Operating Instructions

For your safety, read this information before operating this furnace.
c WARNING: Failure to follow these instructions may result in fire or explosion
causing property damage, personal injury, or loss of life.
WHAT TO DO IN THE EVENT OF AN OIL LEAK:
 Do not try to operate this or any other nearby appliance.
 If present, close the manual oil shutoff valve on the fuel oil supply line.
 Immediately call a qualified heating contractor for service.
 If you cannot reach a qualified heating contractor, call the fuel oil supplier or the
fire department.
DO NOT use this furnace if any component was underwater. Immediately call a qualified
heating contractor to inspect the furnace and replace any part of the furnace control
system that was underwater.
This furnace does not have a pilot light. It is equipped with an electronic ignition system
that automatically lights the burner. DO NOT attempt to light the burner by hand.
TO OPERATE THIS FURNACE:
1) Adjust the room thermostat to the lowest set point and set the operating mode, if
equipped, to "OFF".
2) Turn the manual oil shutoff valve to the open or "ON" position.
3) This furnace is equipped with an electronic ignition system that automatically lights
the burner. DO NOT try to light the burner by hand.
4) Turn on the electric power to the furnace at the disconnecting switch.
5) Adjust the room thermostat to the desired set point and set the operating mode, if
equipped, to "HEAT".
6) If the furnace will not operate, call a qualified heating contractor for service.
TO INTERRUPT (STOP) OPERATION OF THIS FURNACE:
1) Adjust the room thermostat to the lowest set point and set the operating mode, if
equipped, to "OFF".
2) If service will be performed, turn off all electric power to the furnace at the
disconnecting switch.
3) Turn the manual oil shutoff valve to the closed or "OFF" position.

Oil Supply

This oil furnace is designed to use No. 2 or lighter distillate fuel (home heating) oil. A Bio-
fuel mixture may be used but the mixture is not to exceed a B5.