II. GENERAL INSTRUCTIONS - READ BEFORE START OF INSTALLATION
1. The heating output capacity of the furnace proposed for installation should be based on a heat loss
calculation made according to the manuals provided by the Air Conditioning Contractors of America
(ACCA) or the American Society of Heating, Refrigeration and Air Conditioning Engineers, Inc.
(ASHRAE).
2. All local codes and/or regulations take precedence over the instructions in this manual and should be
followed accordingly. In the absence of local codes, installation must conform with these instructions and
regulations of the National Fire Protection Association, and to the provisions of the National Electrical
Code (ANSI/NFPA 70-1999 or latest edition).
3. The installed furnace must be level and positioned in a central location with respect to outlet registers.
It should be located near the chimney to minimize any horizontal run of flue pipe, which may be required.
4. A furnace installed in a residential garage must be installed so the burner and ignition source are
located higher than 18 inches above the floor. The furnace must also be located or protected to avoid
physical damage by vehicles.
WARNING:
This furnace is not to be used as a construction heater.
5. Listed below are definitions of "COMBUSTIBLE MATERIAL" and "NON-COMBUSTIBLE MATERIAL."
Combustible Material: is made of or surfaced with wood, compressed paper, plant fibers, plastics, or
other material that will ignite and burn, whether flame resistant or not.
Non-Combustible Material: is material that is not capable of being ignited and burned. Such materials
consist entirely of, or a combination of, steel, iron, brick, tile, concrete, slate, or glass.
TYPE OF UNIT
MODEL NO.
Highboy
VH8FA119*
VL8*
Lowboy
1
Note:
VH8FA119* front clearance: 8" for Closet, 24" for Alcove.
2
VL8* front clearance: 6" for Closet, 24" for Alcove.
3
The minimum clearances are for fire protection. Clearance for servicing the furnace should be
at least 24 inches.
Table 1: MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
FROM SIDES
OF
FURNACE
0"
0"
TOP &
3
FRONT
SIDES OF
PLENUM
1
8" Note
1"
2
6" Note
1"
7
FROM THE
REAR
FLUE/VENT
8"
0"
8"
0" Note