Siemens UH50 Series Configuration Instructions page 13

Static heat- and cold meter
Hide thumbs Also See for UH50 Series:
Table of Contents

Advertisement

Split version with 1.5m control cable
Split version with 3.0m control cable
Split version with 5.0m control cable
Compact version (until 90° C, with 0.3m control
cable),control cable removable
Split version with 1.5m control cable, control cable
removable
Split version with 3.0m control cable, control cable
removable
Split version with 5.0m control cable, control cable
removable
4. Country / where used
Dial plate for Armenia (Armenian)
Dial plate for Austria (German)
Dial plate for Bosnia-Herzegovina (Croatian)
Dial plate for Belgium (French/Flemish)
Dial plate for Bulgaria (Bulgarian)
Dial plate for Belarus (Russian)
Dial plate for Switzerland (German/French)
Dial plate for China (Chinese)
Dial plate for Serbia and Montenegro (Serbian)
Dial plate for Czech Republic (Czech)
Dial plate for Germany (German)
Dial plate for Denmark (Danish)
Dial plate English neutral
Dial plate for Spain (Spanish)
Dial plate for Finland (Finnish)
Dial plate for Great Britain (English)
Dial plate for Greece (English)
Dial plate for Croatia (Croatian)
Dial plate for Hungary (Hungarian)
Dial plate for Iceland (Icelandic)
Dial plate for Italy (Italian)
Dial plate for Japan (Japanese)
Dial plate for Kazakhstan (Russian)
Dial plate for Lithuania (Lithuanian)
Dial plate for Macedonia (Macedonian)
Dial plate for Mongolia (Mongolian)
Dial plate for The Netherlands (Dutch)
Dial plate for Poland (Polish)
Dial plate for Romania (Romanian)
Dial plate for Russia (Russian)
Dial plate for Sweden (Swedish)
Dial plate for Slovak Repuplic (Slovakian)
Dial plate for Southern Tyrol
Dial plate for Ukraine (Ukrainian)
Dial plate for Uzbekistan (Russian)
5. Manufacturer's label
Logo SIEMENS
6. Sensor type and method of connection
Flow sensor (without temperature sensors)
Sensor Pt100, removable, not mounted in the tube
Sensor Pt100, removable, mounted in the tube
Sensor Pt100, removable, mounting in the tube as an
option
Sensor Pt100, removable, mounted in the tube within
a pocket
Sensor Pt500, removable, not mounted in the tube
Sensor Pt500, removable, mounted in the tube
Sensor Pt500, removable, mounting in the tube as an
option
Sensor Pt500, removable, mounted in the tube within
a pocket
Sensor Pt100, not removable, not mounted in the tube
Sensor Pt100, not removable, mounted in the tube
Sensor Pt100, not removable, mounting in the tube as
an option
Ultraheat / Ultracold UH50
Sensor Pt100, not removable, mounted in the tube
C
within a pocket
D
E
M
7. Sensor type
Without temperature sensors
P
Type DS, 25 bar/150° C/ M10x1 / length 27,5mm,
cable length 1,5m
Q
Type DS, 25 bar/150° C/ M10x1 / length 27,5mm,
cable length 2,5m
R
Type DS, 25 bar/150° C/ M10x1 / length 38mm, cable
Code
length 1,5m (only Pt500)
Type DS, 25 bar/150° C/ M10x1 / length 38mm, cable
AM
length 2,5m (only Pt500)
AT
Type PS, 16 bar/150° C/ Ø5,2x45mm, cable length
BA
1,5m
BE
Type PS, 16 bar/150° C/ Ø5,2x45mm, cable length
5m
BG
Type PL, 25 bar/180° C/ Ø6x100mm, cable length 2m
BY
Type PL, 25 bar/180° C/ Ø6x100mm, cable length 5m
CH
(only Pt500)
CN
Type PL, 25 bar/180° C/ Ø6x150mm, cable length 2m
CS
Type PL, 25 bar/180° C/ Ø6x150mm, cable length 5m
CZ
(only Pt500)
8. Power supply
DE
Without power supply
DK
Standard battery for 6 years
EN
Battery for 6 years for all applications
ES
Battery for 11 years (C cell)
FI
GB
Battery for 11 years
Battery for 16 years (d cell)
GR
HR
Battery without printing of the year
Power supply 24V AC/DC with plug
HU
IS
Power supply 230V AC with 1.5m cable
Power supply 230V AC with 5m cable
IT
Power supply 230V AC with 10m cable
JP
Power supply 110V AC with 1.5m cable
KZ
Power supply 110V AC with 5m cable
LT
MK
Power supply 110V AC with 10m cable
9. Communication module 1
MN
NL
No module in slot1
Analog module in slot1
PL
M-Bus module G4 in slot1
RO
CL-module in slot1
RU
M-bus 30s module in slot1
SE
M-bus module G4-MI with 2 pulse inputs
Pulse module with OptoMOS in slot1
SK
Pulse module in slot1
I2
10. Communication module 2
UA
No module in slot2
UZ
Analog module in slot2
Code
M-Bus module G4 in slot2
06
CL-module in slot2
Code
M-bus 30s module in slot2
0
Pulse module with OptoMOS in slot2
Pulse module in slot2
A
B
Radio module in slot2
Radio module with external antenna in slot2
C
11. Data logger
Without data logger
D
Data logger with 8 channels
E
12. Calibration / conformity
F
certified acc. to national regulations
G
compliant to MID class 2
compliant to MID class 3
H
compliant with CEN 1434, class 2
N
compliant with CEN 1434, class 3
P
compliant acc. to national regulations
13. Energy unit
R
Display: kWh (until qp 10)
Configuration Instructions
Hardware-dependent features
UH 106-101k
S
Code
00
0B
0C
0D
0E
0H
0J
0M
0N
0P
0Q
Code
0
A
B
C
E
F
G
M
N
P
Q
R
S
T
Code
0
A
B
C
D
N
L
P
Code
0
A
B
C
D
L
P
R
X
Code
0
8
Code
CL
M2
M3
T2
T3
TL
Code
A
Page 13 / 15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uh50 ultraheatUh50 ultracoldUh50 flow sensor

Table of Contents