Technical Data - Fast RHE Series Selection, Use, Installation And Maintenance Manual

Heat recovery units with cooling circuit
Table of Contents

Advertisement

RHE MODEL
External maximal air flow
Recovery maximal air flow
Minimum air flow
Supply static available pressure
Exhaust static available pressure
Total heating capacity (rec. + compr.)
Total cooling capacity (rec. + compr.)
Available heating capacity
Available cooling capacity
Recovered heating capacity
Recovered cooling capacity
Refrigerating circuit heating capacity
Refrigerating circuit cooling capacity
Tot. input power in winter
Tot. input power in summer
Sound pressure level
Power supply
RECUPERATOR
Efficiency in winter
Efficiency in summer
FANS
Fans number
Total nominal input power
Total max. absorbed current
Protection class
FILTERS
Classification according to EN779
Weight efficiency
Classification according to EN779 (filters, accessories)
Additional pressure drop for F7 filters (optional)
REFRIGERATING CIRCUIT (COMPRESSOR)
Refrigerant
Compressors input power in winter
Compressors input power in summer
Compressors max. absorbed current
CONDENSATE DRAN PANEL
Diameter of the condensate dran panel charge
Caution: the electronic regulators that are
incorporated in the machine allow to regulate
the air flow in the limits indicated in the
previous table in order to set the system. Once
setting has been completed, the regulators no
Selection, installation, use and maintenance manual
High effi ciency heat recovery unit with cooling circuit - RHE -
[m
3
/h]
[m
3
/h]
[m
3
/h]
(1)
[Pa]
(1)
[Pa]
(3)
[kW]
(2)
[kW]
(3)
[kW]
(2)
[kW]
(3)
[kW]
(2)
[kW]
(3)
[kW]
(2)
[kW]
(3)
[kW]
(2)
[kW]
(4)
[db(A)]
[%]
[%]
[kW]
[A]
IP
[%]
Δ [Pa]
(3)
[kW]
(2)
[kW]
[A]
[in]
longer need to be touched.
1) Fan power supply: 230 V; nominal airflow rate;
without accessories;
(2) Operating conditions: return air 26°C 50%, external
air 34°C 50%;
8

Technical data

10
15
1000
1500
1000
1500
800
1000
320
245
320
245
7,5
14,2
6,6
8,7
2,8
2,9
1,8
3,1
3,6
10,0
2,2
3,2
3,9
4,2
4,4
5,5
2,2
2,4
2,6
2,9
66
69
1-230-50
1-230-50
82
80
82
80
2
2
0,9
0,9
7,6
7,6
55
55
G4
G4
90
90
F7
F7
35
59
R410A
R410A
1,3
1,5
1,7
2,0
10,0
11,0
1"
1"
(3) Operating conditions: return air 20°C 50%, external
air -5°C 80%;
(4) At a free field distance of 1 m with ports canalized.
33
25
2500
3300
3300
2500
2000
2500
140
220
140
220
24,8
33,1
13,8
19,8
3,9
7,0
3,3
5,4
15,3
19,6
4,5
5,8
9,5
13,5
9,3
14,0
4,2
4,9
5,1
6,5
72
75
3+N-400-50
3+N-400-50
73
71
68
65
2
2
2,1
2,1
10,5
10,5
55
55
G4
G4
90
90
F7
F7
58
63
R410A
R410A
2,1
2,8
2,8
4,4
7,0
10,3
1"
1"
GB