Electrical Connection; Connection And Safety Information; 2-Wire System (Output Code 4A, 4As, 4Ax, 4Axs); 3-Wire System (Output Code 0A, 0V) - GEM 3140 Operating Instructions Manual

Pressure transducer
Table of Contents

Advertisement

10 Electrical connection

10 Electrical connection

10.1 Connection and safety information

Devices with cable glands and cable sockets
1. Ensure that the outside diameter of the cable used is
within the permissible clamping range (cable gland M12 x
1.5 cable dia. 3–6.5 mm, cable socket ISO 4400 cable dia.
4.5–10 mm). In addition, make sure that the cable is
seated securely in the cable gland, without any gaps.
2. Use a shielded, twisted multicore cable for the electrical
connection.
Devices with a cable outlet
Comply with the following minimum bend radii when laying
the cable:
Cable without air hose:
Fixed in place: 5 x cable diameter
Flexible use: 10 x cable diameter
Cable with air hose:
Fixed in place: 10 x cable diameter
Flexible use: 20 x cable diameter
On devices with a cable outlet and integrated vent tube, the
PTFE filter on the cable end on the gauge tube must not be
damaged or removed.
▶ Cables used for gauge devices have a vent tube for
equalizing the pressure. Route the cable end into an area
or suitable terminal box that is as free from moisture and
corrosive gases as possible in order to prevent damage.

10.2 2-wire system (output code 4A, 4AS, 4AX, 4AXS)

Pin assignment
ISO 4400
1
3
2
Pin
1
L+, supply voltage
2
L-, supply voltage
3
n. c.
4
PE, protective earth conductor
Circuit diagram
Supply +
P
Supply -
I
GEMÜ 3140
NOTICE
M12x1
2
1
3
4
Description
A
U
10.2.1 Electrical connection
Connect the product in accordance with the pin assign-
ment.

10.3 3-wire system (output code 0A, 0V)

Pin assignment
ISO 4400
1
3
2
Pin
1
L+, supply voltage
2
L-, supply voltage
3
Signal +
4
PE, protective earth conductor
Circuit diagram
P
Supply +
Supply -
Signal +
I/U
10.3.1 Electrical connection
Connect the product in accordance with the pin assign-
ment.

11 Commissioning

1. The device must be properly installed
2. The device must not exhibit any visible defects
B
12 / 16
M12x1
2
3
1
4
Description
U
A/V