Download Print this page

BEA FOCUS Quick Start Manual page 2

Presence sensors for revolving doors, drive-up windows, and sidelite protection

Advertisement

READ BEFORE BEGINNING INSTALLATION/PROGRAMMING/SET-UP
PRECAUTIONS
Shut off all power going to header before attempting any wiring procedures.
!
Maintain a clean and safe environment when working in public areas.
Constantly be aware of pedestrian traffic around the door area.
Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected
reactions by the door.
CAUTION
ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before
handling any board, ensure you dissipate your body's ESD charge.
Always check placement of all wiring before powering up to ensure that moving door parts will not catch
any wires and cause damage to equipment.
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be
performed by BEA, Inc. Unauthorized disassembly or repair:
INSTALLATION
FOCUS
1. Remove end caps and lens from the sensor.
2. Drill mounting holes in the extrusion near the ends of the housing.
See image (right) for mounting hole location.
3. Hold the extrusion in the desired mounting location and mark for pilot holes.
4. Drill pilot holes.
5. Mount sensor using provided screws.
6. Plug harness into the 5 pin connector and wire to the control using the table below for reference.
7. Carefully route the harness out of the housing.
External routing: Use the breakaway notch in the end cap.
Internal routing: Route neatly under end cap.
8. Replace lens and end caps.
FOCUS 2
1. Using mounting template 75.5941, cut hole in desired mounting location.
2. Mount sensor using provided screws. Observe orientation when inserting sensor. Emitter (TX, below) must
be toward vertical stile of the revolving door.
3. Plug harness into the 5 pin connector. Carefully route harness and wire to the control using the table below
for reference.
DIAGRAMS
RX
anti-masking jumper
ANTI-MASKING (see diagram above, right)
ON (factory default): detection occurs even if receiver collects no signal
OFF: no detection occurs if the receiver collects no signal
Page 2 of 4
1. May jeopardize personal safety and may expose one to the risk of electrical shock.
2. May adversely affect the safe and reliable performance of the product resulting in a voided warranty.
5-pin connector
•••••
• • •
WIRE COLOR
yellow
green
TX
white
red
black
CONNECTION
N.C. relay
N.O. relay
COM relay
24 VAC/VDC
24 VAC/VDC
ON
OFF
75.0074.06 FOCUS FOCUS2 20191002
mounting side
(viewed from
right side)

Advertisement

loading

This manual is also suitable for:

Focus 2