TR-Electronic LA Series Assembly Instructions Manual

TR-Electronic LA Series Assembly Instructions Manual

Linear encoder magnetostrictive
Hide thumbs Also See for LA Series:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Linear Encoder
magnetostriktiv
_Grundlegende Sicherheitshinweise
_Verwendungszweck
_Allgemeine Funktionsbeschreibung
_Montagehinweise
Seite 2 - 26
Page 27 - 51
Montageanleitung

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LA Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TR-Electronic LA Series

  • Page 1 Seite 2 - 26 Page 27 - 51 Linear Encoder magnetostriktiv _Grundlegende Sicherheitshinweise _Verwendungszweck _Allgemeine Funktionsbeschreibung _Montagehinweise Montageanleitung...
  • Page 2 Menüauswahlen von Software. ″ < > ″ weist auf Tasten der Tastatur Ihres Computers hin (wie etwa <RETURN>).  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 2 of 51 TR - ELA - BA - DGB - 0004 - 14...
  • Page 3: Table Of Contents

    5.4.1 Berechnungsbeispiel Axialabdichtung ..............23 5.4.2 Berechnungsbeispiel Radialabdichtung ..............24 6 Zubehör ............................25 Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14 Page 3 of 51...
  • Page 4: Änderungs-Index

    LMR-70 und Hinweise für mehrfach redundante Mess-Systeme ergänzt 15.07.19 Kap. „Mechanik Profil-Gehäuseausführung“, Magnetabstand: 18.03.20 allgemeingültiges Bild eingefügt  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 4 of 51 TR - ELA - BA - DGB - 0004 - 14 03/18/2020...
  • Page 5: Allgemeines

    Normen und Richtlinien entwickelt, konstruiert und gefertigt. Eine entsprechende Konformitätserklärung kann bei der Firma TR-Electronic GmbH angefordert werden. Der Hersteller der Produkte, die TR-Electronic GmbH in D-78647 Trossingen, besitzt ein zertifiziertes Qualitätssicherungssystem gemäß ISO 9001. Printed in the Federal Republic of Germany ...
  • Page 6: Verwendete Abkürzungen Und Begriffe

    Internationale Elektrotechnische Kommission National Electrical Code Verband der Elektrotechnik, Elektronik und Informationstechnik  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 6 of 51 TR - ELA - BA - DGB - 0004 - 14...
  • Page 7: Allgemeine Funktionsbeschreibung

    Resultierendes Magnetfeld am Positionssensor ❻ Antwortsignal des Torsionsimpulses ❼ Messwertaufnehmer Empfangsspule ❽ Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14 Page 7 of 51...
  • Page 8: Grundlegende Sicherheitshinweise

    Anlage/Maschine in die das Mess-System eingebaut werden soll, den Bestimmungen der EU-EMV-Richtlinie, den harmonisierten Normen, Europanormen oder den entsprechenden nationalen Normen entspricht.  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 8 of 51...
  • Page 9: Allgemeine Gefahren Bei Der Verwendung Des Produkts

    Insbesondere ist folgende Verwendung untersagt:  In Umgebungen mit explosiver Atmosphäre zu medizinischen Zwecken Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14 Page 9 of 51...
  • Page 10: Gewährleistung Und Haftung

    • Reparaturen dürfen nur vom Hersteller, oder einer vom Hersteller autorisierten Stelle bzw. Person vorgenommen werden.  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 10 of 51 TR - ELA - BA - DGB - 0004 - 14...
  • Page 11: Personalauswahl Und -Qualifikation; Grundsätzliche Pflichten

    Inbetriebnahme und Bedienung festlegen. Beaufsichtigungspflicht bei zu schulendem oder anzulernendem Personal! Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14 Page 11 of 51...
  • Page 12: Sicherheitstechnische Hinweise

    Muss nach der Lebensdauer des Gerätes eine Entsorgung vorgenommen werden, sind die jeweils geltenden landesspezifischen Vorschriften zu beachten.  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 12 of 51 TR - ELA - BA - DGB - 0004 - 14...
  • Page 13: Transport / Lagerung

    Unsachgemäßes Verpackungsmaterial kann beim Transport Schäden am Gerät verursachen. Lagerung Lagertemperatur: siehe Produktdatenblatt Trocken lagern Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14 Page 13 of 51...
  • Page 14: Montagehinweise / Schema

    T2-S5520 49-155-010 X = 8 T1-S3818 49-155-015 X = 3  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 14 of 51 TR - ELA - BA - DGB - 0004 - 14 03/18/2020...
  • Page 15 Positionssensor und dessen Befestigung zu montieren. Die Befestigungsschrauben müssen aus nicht magnetisierbarem Werkstoff sein. Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14...
  • Page 16: Montageschema Der Rohr-Gehäuseausführung

    Umfang offener Positionssensor eingesetzt werden. Optional kann der Wegsensor an der Rohrspitze mit einem Sacklochgewinde M4x5 geliefert werden. Dies kann zur Spitzenlagerung verwendet werden.  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 16 of 51...
  • Page 17: Einbau In Hydraulikzylinder

    Beim Einbau der Linear-Mess-Systeme in die Hydraulikzylinder müssen die gerätespezifischen Daten und Spezifikationen berücksichtigt werden. Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14...
  • Page 18: Abdichtungsvarianten

    Maße sind aus der kundenspezifischen Zeichnung zu entnehmen! Bohrungen ∅ 4 tief (8x45°)  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 18 of 51 TR - ELA - BA - DGB - 0004 - 14...
  • Page 19: Radialabdichtung

    Maße sind aus der kundenspezifischen Zeichnung zu entnehmen! kundenseitige Anforderung, Gewindeaufnahme M18x1.5 Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14...
  • Page 20: Einbauvarianten Bei Magnetisierbarem Material

    Kolbenstange Abstandshalter aus nicht magnetisierbarem Material Magnet (Positionssensor) Mess-System Anschluss-Stecker  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 20 of 51 TR - ELA - BA - DGB - 0004 - 14 03/18/2020...
  • Page 21: Einbaubeispiel Lmr-48, Variante Mit M12-Flanschstecker

    Hülse mit gestecktem Stecker muss nun mit vier M4 Zylinderkopf-Schrauben an den Hydraulik- zylinder montiert werden. Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14 Page 21 of 51...
  • Page 22: Besonderheiten

    Hydrauliksystem bleibt weiterhin unter Druck und langwierige Leer- und Füllzeiten entfallen daher. Beispiel LA-65-H Beispiel LA-46-H  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 22 of 51 TR - ELA - BA - DGB - 0004 - 14...
  • Page 23: Erforderliches Anzugsdrehmoment

    "Maschinenelemente", Roloff/Matek, Tabelle A8-12a (IV) aus "Maschinenelemente", Roloff/Matek, Gleichung 8.20 Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14 Page 23 of 51...
  • Page 24: Berechnungsbeispiel Radialabdichtung

    "Maschinenelemente", Roloff/Matek, Tabelle A8-12a (IV) aus "Maschinenelemente", Roloff/Matek, Gleichung 8.20  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 24 of 51 TR - ELA - BA - DGB - 0004 - 14...
  • Page 25: Zubehör

    6 Zubehör www.tr-electronic.de/produkte/lineargeber/zubehoer.html Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14 Page 25 of 51...
  • Page 26 Zubehör  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 26 of 51 TR - ELA - BA - DGB - 0004 - 14 03/18/2020...
  • Page 27 _Intended use Assembly _General functional description Instructions _Instructions for mounting Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14 Page 27 of 51...
  • Page 28 ″ < > ″ indicates keys on your computer keyboard (such as <RETURN>).  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 28 of 51 TR - ELA - BA - DGB - 0004 - 14...
  • Page 29: Contents

    5.4.2 Calculation example radial sealing ................. 50 6 Accessories ............................. 51 Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14 Page 29 of 51...
  • Page 30: Revision Index

    Chapter “Mechanics profile- housing design”, Magnet distance: 03/18/20 Universal image inserted  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 30 of 51 TR - ELA - BA - DGB - 0004 - 14...
  • Page 31: General Information

    The measuring systems have been developed, designed and manufactured under observation of the applicable international and European standards and directives. A corresponding declaration of conformity can be requested from TR-Electronic GmbH. The manufacturer of the product, TR-Electronic GmbH in D-78647 Trossingen, operates a certified quality assurance system in accordance with ISO 9001.
  • Page 32: Abbreviations And Definitions

    International Electrotechnical Commission National Electrical Code Association for Electrical, Electronic & Information Technologies  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 32 of 51 TR - ELA - BA - DGB - 0004 - 14...
  • Page 33: General Functional Description

    Answer signal of the torsion impulse ❼ Measuring sensor Receipt coil ❽ Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14 Page 33 of 51...
  • Page 34: Basic Safety Instructions

    EU EMC Directive, the harmonized standards, European standards or the corresponding national standards.  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 34 of 51...
  • Page 35: General Risks When Using The Product

    In environments where there is an explosive atmosphere for medical purposes Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14 Page 35 of 51...
  • Page 36: Warranty And Liability

    2.6 Warranty and liability The General Terms and Conditions ("Allgemeine Geschäftsbedingungen") of TR-Electronic GmbH always apply. These are available to the operator with the Order Confirmation or when the contract is concluded at the latest. Warranty and liability claims in the case of personal injury or damage to property are excluded if they result from one or more of the following causes: •...
  • Page 37: Personnel Qualification; Obligations

    • Define clear rules of responsibilities for the assembly, installation, start-up and operation. The obligation exists to provide supervision for trainee personnel ! Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14...
  • Page 38: Safety Informations

    If disposal has to be undertaken after the life span of the device, the respective applicable country-specific regulations are to be observed.  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 38 of 51...
  • Page 39: Transportation / Storage

    Storage temperature: see product data sheet Store in a dry place Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14 Page 39 of 51...
  • Page 40: Instructions For Mounting / Schematic

    T2-S5520 49-155-010 X = 8 T1-S3818 49-155-015 X = 3  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 40 of 51 TR - ELA - BA - DGB - 0004 - 14 03/18/2020...
  • Page 41 The spacer is to be installed between the position sensor and its attachment. The screws must be from not magnetizable material. Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14...
  • Page 42: Assembly Diagram Of The Rod Housing Design

    Optionally the linear transducer can be supplied at the tubing point with a blind hole thread M4x5. This can be used for the rod end bearing.  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany...
  • Page 43: Installation In Hydraulic Cylinders

    At the installation of the measuring system into the hydraulic cylinders the device specific data and specifications must be taken into account. Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14...
  • Page 44: Sealing Options

    Borehole ∅ 4 deep (8x45°) Steel Tube  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 44 of 51 TR - ELA - BA - DGB - 0004 - 14 03/18/2020...
  • Page 45: Radial Sealing

    User requirements, thread M18x1.5 (mating part) Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14 Page 45 of 51...
  • Page 46: Installation Types With Magnetizable Material

    Spacer, consisting of not magnetizable material Magnet (Position sensor) Measuring system Connector plug  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 46 of 51 TR - ELA - BA - DGB - 0004 - 14...
  • Page 47: Mounting Example Lmr-48, Version With M12-Male Connector

    M4 cylinder head screws to the hydraulic cylinder. Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14 Page 47 of 51...
  • Page 48: Unusual Features

    Furthermore the hydraulics system remains under pressure and long emptying times or filling times are therefore dropped. Example LA-65-H Example LA-46-H  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 48 of 51 TR - ELA - BA - DGB - 0004 - 14...
  • Page 49: Required Torque

    (IV) see "Maschinenelemente" (Machine elements), Roloff/Matek, equation 8.20 "oiled easily" Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14 Page 49 of 51...
  • Page 50: Calculation Example Radial Sealing

    "Maschinenelemente" (Machine elements), Roloff/Matek, table A8-12a (IV) see "Maschinenelemente" (Machine elements), Roloff/Matek, equation 8.20 "oiled easily"  TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany Page 50 of 51 TR - ELA - BA - DGB - 0004 - 14...
  • Page 51: Accessories

    6 Accessories www.tr-electronic.com/products/linear-encoders/accessories.html Printed in the Federal Republic of Germany  TR-Electronic GmbH 2007, All Rights Reserved 03/18/2020 TR - ELA - BA - DGB - 0004 - 14 Page 51 of 51...

Table of Contents