While wearing insulated gloves, rotate the handle of the service plug grip and remove the
service plug grip as indicated by the arrows, in the order shown in the illustration.
1
REMOVE INVERTER TERMINAL COVER
CAUTION:
Wear insulated gloves.
Remove the 2
bolts.
Disengage the guide and remove the connector cover
assembly.
NOTICE:
・Do not touch the connector cover assembly
waterproof seal.
・Do not allow any foreign matter or water to enter the
inverter with converter assembly.
CHECK TERMINAL VOLTAGE
CAUTION:
Wear insulated gloves.
NOTICE:
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Using a voltmeter, measure the voltage between the
terminals of the 2 phase connectors.
Standard Voltage: 0 V
HINT:
Use a measuring range of DC 750 V or more on the
voltmeter.
2