1
MOUNTING
WARNING
Risk of injury or damage. Unit will fall if not installed
properly. Follow installation instructions.
• Place unit on 3-inch diameter x 3-inch long tenon
(76mm x 76mm).
• Torque set screws to 10-12 ft-lbs. (14-16 N-m).
2
GLOBE REMOVAL / INSTALLATION
WARNING
Risk of injury. LED light source achieves full intensity
immediately upon being powered on. Do not look
directly at LED light source while energized during install.
• With power disconnected, open access door and
disconnect the LED driver connector.
• Remove globe by rotating counter-clockwise
approximately 90° and raising off locking ring
(see Figure 1).
• Do not rotate by the lens
• Replace globe by lowering into locking ring and
rotating 90° clockwise.
• Verify that orientation of globe is correct. For proper
orientation, see "street/house side" label on globes.
Orientation of the globe may be changed by
loosening tenon set screws and rotating in desired
direction.
• Install set screws (found in pack) for tamper resistant
or 2G applications.
• Reconnect LED driver connector inside base and
replace door.
Set screw
(4 places)
FIGURE 1
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in
connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not
covered sufficiently for the purchaser's purposes, the matter should be referred to GE Lighting.
g
GE Lighting • 1-888-MY-GE-LED
GE Lighting is a subsidiary of the General Electric Company. Evolve and the GE brand and logo are trademarks of the General Electric Company.
© 2013 GE Lighting. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
• Access to terminal board, fusing and photo control
• Unscrew access door screws and pull door forward
• Connect input power leads to terminal block.
• Replace ignitor, fuses and photo control with same
• Close door until locked.
Loosen thumb screws
FIGURE 2
• To maintain high efficiency of the lens, occasional
• Use a mild soap or detergent, which is essentially
• Wash thoroughly, using a soft cloth.
• Rinse with clean, cold water and wipe dry.
Rotate globe
(1 - 888 - 69 - 43 - 533)
3
ACCESS DOOR
(PE option 2, 3 or 4) is through the access door (Figure 2).
to open.
type and rating.
to access terminal
board and PE
receptacle
4
MAINTENANCE / CLEANING
WARNING
Risk of electric shock. Make certain power is off before
attempting any maintenance.
cleaning of the outer lens surface may be needed,
with frequency dependant on local conditions.
neutral pH (pH approximately 6 to 8), non abrasive,
and which contains no chlorinated or aromatic
hydrocarbons.
• www.gelighting.com
PE location
(PE option 2, 3 or 4)
35-201578-196 (Rev. 01/09/18)