WARNING! Ensure the lantern is correctly charged before initial use.
 DO NOT allow children to use the lantern.
 DO NOT use if the battery or the lantern casing is damaged.
When not in use store the lantern in a safe, dry, childproof location.
1.3. BATTERY SAFETY INSTRUCTIONS.
 WARNING! Powered by a sealed lead-acid battery which can be dangerous if not handled with care.
Charge battery prior to first use. The battery pack will have been shipped in a low charge state. Minimum
initial charge time 20 hours.
 DO NOT charge battery when room temperature is below 50°F (10°C) or above 104°F (40°C).
 DO NOT attempt to recharge the battery by means of an engine generator or a DC power source.
 DO NOT short-circuit the battery by linking both terminals with a metal object.
 DO NOT store the battery (or lantern) in locations where the temperature may exceed 104°F (40°C) such
as outside sheds, above heaters, or metal buildings in summer.
 WARNING! Dispose of spent battery correctly and in accordance with local regulations as it contains acid.
DANGER! DO NOT attempt to dismantle the battery pack. For safety and environmental reasons DO NOT
discard in domestic waste or by burning. ONLY discard or recycle according to local waste authority regulations.
 WARNING! DO NOT allow a leaking battery to come into contact with your skin. If you come into contact
with battery fluid take immediate action:
a) Skin contact: Wash immediately with soap and water.
b) Eye contact: Flush eye immediately with cool, clean running water for at least 15 minutes and seek
immediate professional medical attention.
1
.2.
INTRODUCTION
Twin daylight fluorescent tubes suitable for applications where
mains power is unavailable. Tubes can be selected to run
individually or as a pair. Can be powered from rechargeable cells
or from a mains supply cable - both stored integrally. Electronic
control allows unit to be used as an emergency light, switching on
in the event of mains power failure. Lantern includes carry handle
and floor stand or can also be wall mounted.
3.
OPERATION
3.1.
CHARGING THE UNIT.
3.1.1. The unit will charge when plugged into mains supply regardless of function switch position. To achieve
fastest charge put function switch to the 'OFF' position.
3.1.2. Open the power cable compartment at the back of the lantern. Uncoil the power cable and plug it into
the mains power supply. The red LED will light to indicate the presence of mains power.
3.1.3. The battery pack will take approximately 20 hours to charge initially. Subsequent charging times will
depend on the state of discharge of the battery pack.
3.1.4. When charging is complete unplug the mains power cable and stow it back in the compartment. You may
leave the cable connected if you wish to run the lantern from the mains supply.
3.2.
USING THE LANTERN ON mAINS POWER.
3.2.1. Open the power cable compartment at the back of the lantern. Uncoil the power cable and plug it into
the mains power supply. The red LED will light to indicate the presence of mains power.
3.2.2. Select the required tube combination using the function switch. The function switch has three positions:-
1 Tube - OFF -
3.2.3. Should the mains power fail the unit will automatically revert to battery operation.
3.3.
USING THE LANTERN ON BATTERY POWER.
3.3.1. Select the required tube combination using the function switch. The function switch has three positions:-
1 Tube - OFF -
3.3.2. After a full charge the lantern will run for approximately 1hr 30min on two tubes and 3hrs on one tube.
NOTE! The green LED will illuminate whenever a bulb should be lit. If the tubes DO NOT light and
the green LED is illuminated, suspect an unserviceable tube. The lantern has a TEST button
feature to test the tubes. When the TEST button is pressed the tubes should light up. If any
tubes fail to light up, they are likely to be unserviceable.
Both Tubes
Both Tubes
Original Language Version
Tubes:
Tube Length:
Mains Supply:
Battery:
Operating Time: 1 Tube:
2 Tubes:
Replacement Tube:
2 x 20W
590mm
230V 50Hz 40mA
6V 4.5Ah
3hrs
1hr 30min
ML18/36.V3-B
ML18/36.V3
Issue: 1 - 27/07/11