Helios ecovent verso KWL 45 RSF Installation And Operating Instructions Manual

Helios ecovent verso KWL 45 RSF Installation And Operating Instructions Manual

Heat recovery and ec-motor technology for wall installation
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Helios Ventilatoren
MONTAGE- UND BETRIEBSVORSCHRIFT
Rohbauset Fassade
KWL 45 RSF
KWL 45 RSF-L
- Wärmerückgewinnung und EC-Technik
für den Wandeinbau.
NR. 82 327.002
D

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ecovent verso KWL 45 RSF and is the answer not in the manual?

Questions and answers

Summary of Contents for Helios ecovent verso KWL 45 RSF

  • Page 1 Helios Ventilatoren MONTAGE- UND BETRIEBSVORSCHRIFT NR. 82 327.002 Rohbauset Fassade KWL 45 RSF KWL 45 RSF-L - Wärmerückgewinnung und EC-Technik für den Wandeinbau.
  • Page 2 DEUTSCH...
  • Page 3: Table Of Contents

    Montage- und Betriebsvorschrift Rohbauset Fassade KWL 45 RSF / KWL 45 RSF-L Inhaltsverzeichnis KAPITEL 1. SICHERHEIT ..............Seite 3 Wichtige Informationen .
  • Page 4: Wichtige Informationen

    Medien, längere Stillstandzeiten, starke Verschmutzung, übermäßige Beanspruchung durch klimati- sche, technische oder elektronische Einflüsse geeignet. Gleiches gilt für die mobile Verwendung der Lüftungsgeräte (Fahr-, Flugzeuge, Schiffe, usw.). Ein Einsatz unter diesen Bedingungen ist nur mit Einsatzfreigabe seitens Helios mög- lich, da die Serienausführung hierfür nicht geeignet ist.
  • Page 5: Garantieansprüche - Haftungsausschluss

    KAPITEL 2 Alle Ausführungen dieser Dokumentation müssen beachtet werden, sonst entfällt die Gewährleistung. Gleiches gilt für Haftungsansprüche an Helios. Der Gebrauch von Zubehörteilen, die nicht von Helios empfohlen oder angeboten wer- ALLGEMEINE HINWEISE den, ist nicht statthaft. Eventuell auftretende Schäden unterliegen nicht der Gewährleistung. Veränderungen und Umbauten am Gerät sind nicht zulässig und führen zum Verlust der Konformität, jegliche Gewährleistung und Haftung...
  • Page 6: Lieferumfang

    Montage- und Betriebsvorschrift Rohbauset Fassade KWL 45 RSF / KWL 45 RSF-L Lieferumfang KAPITEL 3 Das Rohbauset Fassade erst unmittelbar vor dem jeweiligen Montageschritt bzw. Einbau aus der Verpackung entneh- men um mögliche Beschädigungen und Verschmutzungen zu vermeiden. LIEFERUMFANG Abb.1 Rohbauset Fassade KWL 45 RSF Best.-Nr.
  • Page 7: Positionierung

    Montage- und Betriebsvorschrift Rohbauset Fassade KWL 45 RSF / KWL 45 RSF-L Positionierung KAPITEL 4 Folgende Abstände zur Wand und Decke sind bei der Positionierung des Lüftungsgerätes bzw. der Kernlochbohrung zu beachten (Abb.4). POSITIONIERUNG/ EINBAU Abb.4 Einbau Rohbauset Das Lieferset erst unmittelbar vor dem Einbau aus der Verpackung entnehmen um mögliche Beschädigungen und Ver- schmutzungen beim Transport sowie auf der Baustelle zu vermeiden.
  • Page 8: Montageschritt Aussenwand: - Fassadenblende

    Montage- und Betriebsvorschrift Rohbauset Fassade KWL 45 RSF / KWL 45 RSF-L Abb.7 SCHNITTDARSTELLUNG 5. Ringspalt „ Innen und „ Außen” mit nichtdrückendem Montageschaum einschäumen (Abb.7/8). Nach ausreichender Trocknungszeit, die überstehenden Fixierkeile und überschüssigen Montageschaum entfernen. 6. HINWEIS: Zur Kabeldurchführung bei Bedarf EPP-Material (unterer Frontkeil) und evtl. Reste vom Montageschaum HINWEIS entfernen (Abb.8).
  • Page 9: Kondensatableitung

    Montage- und Betriebsvorschrift Rohbauset Fassade KWL 45 RSF / KWL 45 RSF-L 4. Blende abnehmen und Blendenrahmen zentriert über der Wandöffnung ausrichten, Bohrbild anzeichnen und bohren (Abb.12). 5. Blendenrahmen waagerecht ausrichten (Abb.12) und an der Wand festschrauben (Edelstahl-Schrauben bauseits). Anschließend die Blende wieder aufstecken und festschrauben (Abb.13). Abb.12 Abb.13 AUSSENWAND...
  • Page 10: Schaltplanübersicht

    Montage- und Betriebsvorschrift Rohbauset Fassade KWL 45 RSF / KWL 45 RSF-L Schaltplanübersicht Abb.16 SS-1093 Betrieb mit bis zu 8 x KWL EC 45 mit 2 x KWL 45 SNU parallel KWL EC 45: Start Zuluft KWL EC 45: Start Abluft 6 - GND 8 - + 12V 10 - PWM Start Zuluft...
  • Page 11 Montage- und Betriebsvorschrift Rohbauset Fassade KWL 45 RSF / KWL 45 RSF-L Abb.17 SS-1091 Service Micro USB KWL 45 BEU 8 9 10 11 - / GND M2... - / GND M1... - / GND 12V= Schutzklasse 3, SELV-Sicherheitskleinspannung Externer Kontakt, Funktionen siehe in der MBV-Montage und Betriebsvorschrift Betrieb mit 2 x KWL EC 45 mit 1 x KWL 45 SNU KWL EC 45: M1 - Start Zuluft KWL EC 45: M2 - Start Abluft...
  • Page 12 HELIOS Ventilatoren GmbH + Co KG · Lupfenstraße 8 · 78056 VS-Schwenningen HELIOS Ventilateurs · Le Carré des Aviateurs · 157 avenue Charles Floquet · 93155 Le Blanc Mesnil Cedex CH HELIOS Ventilatoren AG · Tannstrasse 4 · 8112 Otelfingen GB HELIOS Ventilation Systems Ltd.
  • Page 13 Helios Ventilatoren INSTALLATION AND OPERATING INSTRUCTIONS NO. 82 327 Installation kit facia KWL 45 RSF KWL 45 RSF-L - Heat recovery and EC-motor technology for wall installation.
  • Page 14 ENGLISH...
  • Page 15 Installation and operating instructions Installation kit facia KWL 45 RSF / KWL 45 RSF-L Table of contents CHAPTER 1. SAFETY ...............Page 3 Important information .
  • Page 16: Chapter 1. Safety

    The same applies for the mobile use of fans (vehicles, aircraft, ships, etc.). Usage under these conditions is only possible with release approval from Helios, as the standard version is not suitable in this case. – Improper, prohibited use: Any use other than the intended use is not permitted! The conveying of solid matter or solid matter content >...
  • Page 17: Chapter 2. General Instructions

    CHAPTER 2 All versions of this documentation must be observed, otherwise the warranty shall cease to apply. The same applies to liability claims against Helios. The use of accessory parts, which are not recommended or offered by Helios, is not GENERAL permitted.
  • Page 18: Chapter 3. Scope Of Delivery

    Installation and operating instructions Installation kit facia KWL 45 RSF / KWL 45 RSF-L Scope of delivery CHAPTER 3 Leave the installation kit facia in its packaging until just before the respective installation step or installation in order to prevent any possible damage and contamination. SCOPE OF DELIVERY fig.1 Installation kit facia...
  • Page 19: Chapter 4. Positioning

    Installation and operating instructions Installation kit facia KWL 45 RSF / KWL 45 RSF-L Positioning CHAPTER 4 The following distances to walls and ceilings must be observed when positioning the ventilation unit or core hole drilling (fig.4). POSITIONING/ INSTALLATION fig.4 Wall distance at least 250 Ductwork for cables...
  • Page 20: Installation Step External Wall: - Facia Panel

    Installation and operating instructions Installation kit facia KWL 45 RSF / KWL 45 RSF-L fig.7 (Shortened up to 300 mm) Internal wall Outside wall Wall installation sleeve Installation foam ng wedge Front wedge for condensate drain Ductwork for cables SECTION VIEW 5.
  • Page 21: Chapter 5. Note Condensate Drainage

    Installation and operating instructions Installation kit facia KWL 45 RSF / KWL 45 RSF-L 4. Remove panel and position the panel frame centrally over the wall opening, mark the drill holes and drill (fig.12). 5. Place panel frame in horizontal position (fig.12) and screw into the wall (stainless steel screws must be provided on site).
  • Page 22: Circuit Diagram Overview

    Installation and operating instructions Installation kit facia KWL 45 RSF / KWL 45 RSF-L Circuit diagram overview fig.16 SS-1093 Betrieb mit bis zu 8 x KWL EC 45 mit 2 x KWL 45 SNU parallel KWL EC 45: Start Zuluft KWL EC 45: Start Abluft 6 - GND 8 - + 12V...
  • Page 23 Installation and operating instructions Installation kit facia KWL 45 RSF / KWL 45 RSF-L fig.17 SS-1091 Service Micro USB KWL 45 BEU 8 9 10 11 - / GND M2... - / GND M1... - / GND 12V= Schutzklasse 3, SELV-Sicherheitskleinspannung Externer Kontakt, Funktionen siehe in der MBV-Montage und Betriebsvorschrift Betrieb mit 2 x KWL EC 45 mit 1 x KWL 45 SNU...
  • Page 24 HELIOS Ventilatoren GmbH + Co KG · Lupfenstraße 8 · 78056 VS-Schwenningen HELIOS Ventilateurs · Le Carré des Aviateurs · 157 avenue Charles Floquet · 93155 Le Blanc Mesnil Cedex CH HELIOS Ventilatoren AG · Tannstrasse 4 · 8112 Otelfingen GB HELIOS Ventilation Systems Ltd.
  • Page 25 Helios Ventilateurs NOTICE DE MONTAGE ET D’UTILISATION N° 82 327.002 Façade kit gros oeuvre KWL 45 RSF KWL 45 RSF-L - Récupération de chaleur et technique EC pour montage mural...
  • Page 26 FRANÇAIS...
  • Page 27 Notice de montage et d’utilisation Façade kit gros oeuvre KWL 45 RSF / KWL 45 RSF-L Sommaire CHAPITRE 1. SÉCURITÉ ..............Page 3 Informations importantes .
  • Page 28: Informations Importantes

    à des contraintes techniques et électro- niques. Une demande d’approbation est donc requise par Helios : les modèles de série n’étant pas prévus pour cet usage. Idem pour le déplacement des ventilateurs (voitures, avions, bateaux, etc.).
  • Page 29: Garantie - Réserves Du Constructeur

    CHAPITRE 2 Si toutes les consignes indiquées dans cette notice ne sont pas correctement respectées, la garantie s’annule. Idem pour les garanties constructeur Helios. L’utilisation d’accessoires, non fournis, non conseillés ou non proposés par INFORMATIONS Helios, est interdite. Tous changements ou transformations effectués sur l’appareil sont interdits, altèrent sa conformité.
  • Page 30: 3.0 Contenu De La Livraison

    Notice de montage et d’utilisation Façade kit gros oeuvre KWL 45 RSF / KWL 45 RSF-L 3.0 Contenu de la livraison CHAPITRE 3 Pour éviter d'endommager ou de salir les pièces, nous vous conseillons de sortir le kit de façade gros oeuvre et ses COMMANDE accessoires de son emballage qu'au moment de la mise en oeuvre de chaque pièce.
  • Page 31: Positionnement

    Notice de montage et d’utilisation Façade kit gros oeuvre KWL 45 RSF / KWL 45 RSF-L Positionnement CHAPITRE 4 Les distances mur/plafond suivantes sont à respecter lors du positionnement de l’unité de ventilation et du carrotage (fig. 4). POSITIONNEMENT/ MONTAGE Fig.
  • Page 32: Évacuation Des Condensats

    Notice de montage et d’utilisation Façade kit gros oeuvre KWL 45 RSF / KWL 45 RSF-L Fig. 7 (rétractable jusqu’à 300 mm) Mur extérieur Mur intérieur Mousse de montage Manchon mural Cale de montage Cale avant pour évacua- tion des condensats Rainure COUPE 5.
  • Page 33: Raccordement Électrique

    Notice de montage et d’utilisation Façade kit gros oeuvre KWL 45 RSF / KWL 45 RSF-L 4. Retirer la grille et centrer le cadre de la grille sur l'ouverture du mur, tracer les trous à forer et percer (fig. 12). 5.
  • Page 34 Notice de montage et d’utilisation Façade kit gros oeuvre KWL 45 RSF / KWL 45 RSF-L Plan de raccordement Fig. 16 SS-1093...
  • Page 35 Notice de montage et d’utilisation Façade kit gros oeuvre KWL 45 RSF / KWL 45 RSF-L Fig. 17 SS-1091...
  • Page 36 HELIOS Ventilatoren GmbH + Co KG · Lupfenstraße 8 · 78056 VS-Schwenningen HELIOS Ventilateurs · Le Carré des Aviateurs · 157 avenue Charles Floquet · 93155 Le Blanc Mesnil Cedex CH HELIOS Ventilatoren AG · Tannstrasse 4 · 8112 Otelfingen GB HELIOS Ventilation Systems Ltd.

This manual is also suitable for:

Ecovent verso kwl 45 rsf-l

Table of Contents