5. Power Requirements
Two AAA alkaline Batteries
Power consumption: Less than 25mA
Battery Life: Two AAA 1.5V, 800mAh alkaline batteries could be continuously operated as long as 16 hours.
6. Environment Requirements
Operation Temperature: 5 ℃~40℃
Storage/ Transport Temperature: -20 ℃~+55℃
Ambient Humidity: ≤80% no condensation in operation; ≤93% no condensation in storage/transport
Atmosphere pressure: 86kPa~106kPa
7. Equipment data update period
As shown in the following figure. Data update period of slower average is 8s.
8. Classification
According to the type of protection against electric shock: INTERNALLY POWERED EQUIPMENT;
According to the degree of protection against electric shock: TYPE BF APPLIED PART, (applied part: the rubber hole of the device);
According to the degree of protection against ingress of water: IPX1
According to the mode of operation: CONTINUOUS OPERATION
Declaration
Possible Problems and Solutions
P
o r
b
e l
m
s
P
o
s s
b i
e l
SpO
or PR can not
1. Finger is not inserted correctly
2
be shown normally
2. User's SpO
value is too low to be measured
2
SpO
or PR is shown
1. Finger might not be inserted deep enough.
2
unstably
2. Excessive user movement
1. No battery or low power of battery
The oximeter cannot
2. Batteries might be installed incorrectly
be powered on
3. The oximeter might be damaged
1. The product is automatically powered off when
Indication lamps are
no signal is detected longer than 8 seconds
suddenly off
2. The battery power is too low to work
"Error7" is
Err 7 means all the emission LED or reception diode is
displayed on screen
damaged.
Symbol Definitions
S
y
m
b
l o
D
f e
n i
t i
o i
n
Type BF applied part.
Protected against dripping water.
PR
bpm
Pulse rate (BPM)
No SpO
Alarm
2
Storage temperature and relative
humidity
Date of Manufacture
Waste electrical and electronic
equipment
Box Contents
1.
Fingertip pulse oximeter
2.
One lanyard
3.
Two AAA batteries
4.
One instruction manual
Applicable Models
CCI-300C-BO-DLX CCI-300C3-Blue-DLX
Notes:
1.
The illustrations used in this manual may differ slightly from the appearance of the actual product.
2.
The specifications are subject to change without prior notice.
Concord Health Supply, Inc.
Off: 888-970-2999
Fax: 888-970-8999
www.ConcordHealthSupply.com
ALL RIGHTS RESERVED
Revised Date: September 25, 2019
e r
s a
o
n
S
l o
t u
1. Retry by inserting the finger r
2. There is excessive illumination
3. Try some more times. If you can make sure no
problem exist in the product, please go to a
hospital timely for exact diagnosis.
1. Retry by inserting the finger
2. Be calmness
1. Please replace batteries
2. Please reinstall the batteries
3. Please contact with local customer service
centre
1. Normal
2. Replace the batteries
Please contact with local customer service centre
S
y
m
b
l o
D
f e
n i
t i
o i
n
Attention
﹪SpO
Oxygen saturation
2
Low power indication
SN
Serial No.
Follow instruction for use
Manufacturer's information
o i
n

Advertisement

loading

This manual is also suitable for:

Black ox deluxeCci-300c3-blue-dlxCci-black-ox-dlx