Verify Operation - Omnitron Systems iConverter GM3 Quick Start Manual

2 and 3 port network interface devices
Table of Contents

Advertisement

WARNING!!!
NEVER ATTEMPT TO OPEN THE CHASSIS OR
SERVICE THE POWER SUPPLY. OPENING THE
CHASSIS MAY CAUSE SERIOUS INJURY OR DEATH.
THERE ARE NO USER REPLACEABLE OR
SERVICEABLE PARTS IN THIS UNIT.
Make sure to disconnect the power and ground cables before removing the
equipment.
4) Connect Cables
a.
When using SFP models, insert the SFP fiber transceiver into the SFP
receptacle on the front of the module (see the SFP Data Sheet 091-17000-001
for supported Fast/Gigabit transceivers).
NOTE: The release latch of the SFP fiber transceiver must be in the closed
(up) position before insertion.
The module has the ability to detect the speed and automatically configure
the port to match the speed of approved SFP transceivers. Some SFP fiber
transceivers will need to be configured using the CLI portattribute commands
to configure the speed of the port to match the speed of the installed SFP
transceiver.
b.
Connect an appropriate multimode or single-mode fiber cable to the fiber port
on the front of the module. It is important to ensure that the transmit (TX) is
attached to the receive side of the transceiver at the other end and the receive
(RX) is attached to the transmit side. When using single-fiber (SF) models, the
TX wavelength must match the RX wavelength at the other end and the RX
wavelength must match the TX wavelength at the other end.
c.
Connect the Ethernet 10/100/1000 RJ-45 port using a Category 5 or better
cable to an external 10BASE-T, 100BASE-TX or 1000BASE-T Ethernet device.
Page 15

5) Verify Operation

Verify the module is operational by viewing the LED indicators.
LED Function
Color
"Legend"
Power
Green
No power
"PWR"
P1 Link Activity
Green
Port not linked at 100M
"100"
P1 Link Activity
Green
Port not linked at 1000M
"1000"
P1 Link Activity
Green
Port not linked at 10M
"100" and "1000"
Test/Alarm
Green
Reserved
"Tst/Alm"
Management Mode
Green
N/A
"Msr/Slv"
P2 Link Activity
Green
Port not linked at 100M
"100"
P2 Link Activity
Green
Port not linked at 1000M
"1000"
P2 Link Activity
Green
Port not linked at 10M
"100" and "1000"
LED Indicators for 2-Port SFP/UTP and UTP/UTP Models
LED Function
Color
"Legend"
Power
Green
No power
"PWR"
P1 Link Activity
Green
Port not linked at 100M
"100"
P1 Link Activity
Green
Port not linked at 1000M
"1000"
P1 Link Activity
Green
Port not linked at 10M
"100" and "1000"
P2 Link Activity
Green
Port not linked at 100M
"100"
P2 Link Activity
Green
Port not linked at 1000M
"1000"
P2 Link Activity
Green
Port not linked at 10M
"100" and "1000"
Test/Alarm
Green
Reserved
"Tst/Alm"
Management Mode
Green
N/A
"Msr/Slv"
LED Indicators for 2-Port SFP/SFP Models
OFF State
ON/Blinking State
ON: Module has power
ON: Port linked at 100M
Blinking: Data activity
ON: Port linked at 1000M
Blinking: Data activity
ON: Port linked at 10M
Blinking: Data activity
Reserved
ON: Master (normal)
5 Hz Blinking: Remote Slave
ON: Port linked at 100M
Blinking: Data activity
ON: Port linked at 1000M
Blinking: Data activity
ON: Port linked at 10M
Blinking: Data activity
OFF State
ON/Blinking State
ON: Module has power
ON: Port linked at 100M
Blinking: Data activity
ON: Port linked at 1000M
Blinking: Data activity
ON: Port linked at 10M
Blinking: Data activity
ON: Port linked at 100M
Blinking: Data activity
ON: Port linked at 1000M
Blinking: Data activity
ON: Port linked at 10M
Blinking: Data activity
Reserved
ON: Master (normal)
5 Hz Blinking: Remote Slave
Page 16

Advertisement

Table of Contents
loading