  • Page 1 MIMO88 DIGITAL MATRIXES Installation Digital Matrix USER MANUAL v.20200828...
  • Page 2: Table Of Contents

    INDEX IMPORTANT REMARK ......................3 IMPORTANT SAFETY INSTRUCTIONS ................3 IMPORTANT NOTE ......................... 5 INTRODUCTION ........................5 INSTALLATION ........................6 5.1. Location, assembly, ventilation ....................6 5.2. Connection to an AC outlet and switching on ..............6 5.3. Signal input connections ......................7 5.4.
  • Page 3: Important Remark

    IMPORTANT REMARK The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
  • Page 4 9. Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety.
  • Page 5: Important Note

    • 8 balanced LINE outputs. • 2 MONITOR outputs that can be used as auxiliaries. • Expandable to 16 inputs/16 outputs by linking a second MIMO88 unit (getting a real 16 inputs and 16 outputs matrix). Connect the two units using a CAT5 crossover cable (100 meters maximum distance).
  • Page 6: Installation

    The MIMO88 has been especially designed to be installed in a standard 19" rack, taking up 1U. It is very important not to enclose the MIMO88 or expose it to extreme temperatures as it generates heat. It’s also necessary to promote the passage of fresh air through the ventilation holes of the chassis, leaving at least one rack unit off between each device and installed above and below it in the rack frame.
  • Page 7: Signal Input Connections

    5.3. Signal input connections The rear panel of the MIMO88 offers 8 balanced analogue signal inputs, "IN" (9), accepting both line and microphone level signals. Input signal type selection and management are carried out from EclerNet Manager application. Please refer to the EclerNet Manager software manual for more information.
  • Page 8: Ethernet Port For Programming And Control

    To work in 16x16 mode, one of the two coupled MIMO88 units (linked by BUS LINK) assumes the role of MASTER and the other one the role of SLAVE. MASTER or SLAVE mode is set by the selector (13) located on the rear panel of each unit. In single MIMO88 setups, selector position is irrelevant.
  • Page 9: Remote Ports 1 And 2 For Digital Remote Controls

    CAN LOW. Refer to the remote device documentation (WPTOUCH, MPAGE16, etc) for more information about your connection and controls. Refer to the EclerNet Manager application manual for more information about MIMO88 programming to manage remote devices connected to REMOTE1 or REMOTE2.
  • Page 10: Gpi Remote Control Ports

    5.8. GPI Remote Control Ports The rear panel of the MIMO88 offers 8 GPI inputs (16) for 0-10 VDC continuous control voltage. Each of these inputs can be connected to an external physical device (potentiometer, contact closure, continuously variable voltage 0-10V DC, etc.) and assigned to a MIMO88 function, as for example: •...
  • Page 11: Gpo Remote Control Ports

    The rear panel of the MIMO88 offers 8 NO/NC (normally open/ normally closed) relay outputs (17). Each of these outputs may be assigned to a MIMO88 function, such as a button of EclerNet Manager (MUTE key, SOLO key, etc.). This makes it possible to interact with external devices such as projection screen motors or movable partitions, lights, sirens, other equipment GPI entries, etc.3.10.
  • Page 12: Front Panel Controls And Led Indicators

    5.11. Front panel controls and LED indicators The following elements are available on the MIMO88 front panel: • MONITOR output (marked with a headphones symbol): it produces the same monitoring signal already available via the rear panel screw terminal block, but here on a ¼"...
  • Page 13: Cleaning

    • If no MASTER is connected (or if connected equipment is another SLAVE), the LED slowly toggles between orange (800ms) and red (200ms) o POWER: illuminates when the unit is in operation. It flashes if there is an error in the unit or if firmware is not correct. It also flashes when you update firmware CLEANING The front panel should not be cleaned with dissolvent or abrasive substances because...
  • Page 14: Function Diagram

    FUNCTION DIAGRAM...
  • Page 15: Technical Characteristics

    TECHNICAL CHARACTERISTICS 2x 32/64bit Sampling Rate 48kHz Latency IN to OUT <2.9ms (+1ms for 16x16) Converters Resolution 24bit AKM Dynamic Range AD:110dB, DA: 115dB Analog 8 Input/Output (expandable to 16x16) Terminal block (Symmetrical) 2 monitor output Terminal block (Symmetrical) Headphones related Jack ¼...
  • Page 16 THD+Noise @ 1kHz, -40dBV input (mic.) <0.008% Output Noise floor FFT (20Hz - 20kHz) better than 115dB Interchannel crosstalk (20Hz - 20kHz) better than 90dB (100dB typ.) Channel Leakage (20Hz - 20kHz) better than 100dB (115dB typ.) CMRR 20Hz- 20kHz 65dB typ.
  • Page 17 Parametric Eq. Types Bypass / On-Off all channels (4 max per input) Param Eq. Freq: 20Hz-20kHz; (8 max per output) Gain: -60/+12 dB Q: 0.3 to 200 Low & High Shelf 6/12 dB/oct Low & High Pass 6/12 dB/oct All Pass 1/2 order High &...
  • Page 18 Input Compressor / Limiter (x8) Bypass On-Off Threshold: from –36 dBV to +18 dBV Ratio: 1:1 to inf:1 (limiter) Knee: hard / soft Attack time: from 0,1 ms. to 500 ms. Release time: from 10 ms. to 1000 ms. Make up gain: from 0 to +10 dB Input Frequency Shifter (x8) Per input.
  • Page 19 Mix Matrix Size: 8x8 (1-MIMO88) Size: 16x16 (2-MIMO88 with expan. link bus) Vol: Input, Output, Crosspoint Mute: Set/Clear individual, row, column, all Input /output Mono/stereo selector Meter: Input /output VU and clip Pager (x4) Input: IN1 to IN8 (or to IN16 in 16x16)
  • Page 20 Miscellaneous Management Connectivity Ethernet Base-Tx 10/100Mb Auto X-Over CAT5 up to 100m. Expansion LINK BUS (16x16 ch.) Proprietary over CAT5, Xover cable up to 100m. Remote Bus 2, over twisted pairs; up to 1km (see specific specs.) 8, from 0 to 10VDC or TTL level 8, 3 poles isolated relay;...
  • Page 21: Block Diagram

    BLOCK DIAGRAM...
  • Page 22 NEEC AUDIO BARCELONA S.L. reserves the right to make changes or improvements in the design or manufacturing that may affect these product specifications. For technical queries contact your supplier, distributor or complete the contact form on our website, Support / Technical requests. Motors, 166‐168 08038 Barcelona ‐ Spain ‐ (+34) 932238403 | information@ecler.com www.ecler.com...