In the following example, a storage "just a bunch of disks" (JBOD) has one target and two
LUNs attached to one port of a dual-port Converged Network Adapter.
{0} ok show-disks
a) /pci@7c0/pci@0/pci@8/SUNW,qlc@0,3/fp@0,0/disk
b) /pci@7c0/pci@0/pci@8/SUNW,qlc@0,2/fp@0,0/disk
c) /pci@7c0/pci@0/pci@1/pci@0,2/LSILogic,sas@2/disk
d) /pci@7c0/pci@0/pci@1/pci@0/ide@8/cdrom
e) /pci@7c0/pci@0/pci@1/pci@0/ide@8/disk
q) NO SELECTION
Enter Selection, q to quit: b
{0} ok select /pci@7c0/pci@0/pci@8/SUNW,qlc@0,2
QLogic QLE8142 Host Adapter FCode(SPARC): 3.15 2013-01-11 19:29
ISP Firmware version 5.03.02
MPI FW version 1.39.00
{0} ok show-children
Adapter portID - 11401
************** Fabric Attached Devices **************
Dev# 0(0)
PortID 10500
LUN
0(0)
DISK SUN
LUN
1(1)
DISK SUN
LUN
2(2)
DISK SUN
LUN
3(3)
DISK SUN
LUN
4(4)
DISK SUN
LUN
5(5)
DISK SUN
LUN
6(6)
DISK SUN
LUN
7(7)
DISK SUN
LUN
8(8)
DISK SUN
LUN
9(9)
DISK SUN
To Verify Proper Installation (Oracle x86 Systems)
1.
During system power-on initiation, the following system booting BIOS
initialization screen is displayed.
QLogic Corporation
QLE8152 PCI3.0 Fibre Channel ROM BIOS version 2.14
Copyright (c) QLogic Corporation 1992-2009. All rights reserved.
www.qlogic.com
Press <CTRL-Q> or <ALT-Q> for Fast!UTIL
To Verify Proper Installation (Oracle x86 Systems)
Port WWN 200600a0b819e3b8
CSM100_R_FC
0619
CSM100_R_FC
0619
CSM100_R_FC
0619
CSM100_R_FC
0619
CSM100_R_FC
0619
CSM100_R_FC
0619
CSM100_R_FC
0619
CSM100_R_FC
0619
CSM100_R_FC
0619
CSM100_R_FC
0619
Chapter 2 • Hardware Installation and Removal
31