Smitec POSYC 3303 Instructions For Installation, Use And Maintenance Manual

Smitec POSYC 3303 Instructions For Installation, Use And Maintenance Manual

Advertisement

Quick Links

POSYC 3303 industrial PC
Smitec S.p.A., viale Vittorio Veneto 4, 24016 San Pellegrino Terme (BG), Italy, www.smitec.it
Installation, use and maintenance manual
BEFORE STARTING UP THE POSYC 3303 INDUSTRIAL PC, CAREFULLY READ THIS
MANUAL AND FOLLOW ALL INSTRUCTIONS, IN ORDER TO ENSURE MAXIMUM
SAFETY
INDUSTRIAL COMPUTERS
The technical data and the drawings in this manual might have been modified later; always
refer to the latest version.
Ver. 1.02
Installation, use and maintenance manual - EN
POSYC 3303
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the POSYC 3303 and is the answer not in the manual?

Questions and answers

Summary of Contents for Smitec POSYC 3303

  • Page 1 POSYC 3303 industrial PC Installation, use and maintenance manual - EN Smitec S.p.A., viale Vittorio Veneto 4, 24016 San Pellegrino Terme (BG), Italy, www.smitec.it Installation, use and maintenance manual BEFORE STARTING UP THE POSYC 3303 INDUSTRIAL PC, CAREFULLY READ THIS...
  • Page 2: Table Of Contents

    POSYC 3303 industrial PC Installation, use and maintenance manual - EN Summary 1 Preface ............................... 3 2 General warnings ............................4 3 Safety instructions ............................ 6 3.1 General information ..........................6 3.2 Precautions during handling and assembly ..................6 4 Product description ..........................7 4.1 Front view ............................
  • Page 3: Preface

    POSYC 3303 industrial PC Installation, use and maintenance manual - EN 1 Preface This manual provides all necessary information for the installation, use and maintenance of POSYC 3303 in- dustrial PC. The instructions included in this manual are addressed to the following professionals:...
  • Page 4: General Warnings

    MANUAL. THE EQUIPMENT CANNOT BE USED FOR PURPOSES DIFFERENT THAN THE ONES DESCRIBED IN THIS MANUAL; SMITEC S.p.A. SHALL NOT BE HELD RESPONSIBLE FOR ANY DAMAGES, INCON- VENIENCES OR ACCIDENTS DUE TO THE NON-COMPLIANCE WITH THESE PRESCRIPTIONS. In order to make the manual consultation easier, the following symbols have been adopted: Indication of “PROHIBITED ACTION”.
  • Page 5 POSYC 3303 industrial PC Installation, use and maintenance manual - EN performing the activities described later on in this manual. These prescriptions constitute the prescribed method of operating the device, in a way that is safe for person- nel, equipments and environment.
  • Page 6: Safety Instructions

    Make sure that the personnel is qualified and adequately informed about the risks he may run and how to avoid them. POSYC 3303 industrial PC can be used only after the classification of the machine operat- ing area and after checking the safety levels, which must correspond to the assembly safety levels.
  • Page 7: Product Description

    POSYC 3303 industrial PC Installation, use and maintenance manual - EN 4 Product description The POSYC is a personal computer based on Intel® 64 hardware designed primarily to facilitate human-ma- chine interfacing (HMI) in an industrial environment, but its characteristics make it suitable also for different us- es, such as information terminals and automation systems in general.
  • Page 8: Front View

    POSYC 3303 industrial PC Installation, use and maintenance manual - EN 4.1 Front view Ver. 1.02...
  • Page 9: Technical Data

    All the technical data in this section correspond to the hardware configuration of the POSYC 321X manufactured on the date when this manual was drawn up. To improve or update this product, SMITEC S.p.A. reserves the right to modify its technical features without notice. 5.1 Environmental specifications Operating temperature 0°...
  • Page 10: Mechanical Specifications

    1.28 kg 5.3.1 Front view The computers Posyc 3303 need to be fixed on a stable and rigid panel provided with 4xM3 metal threaded hole, min. 1.5mm deep. Use 4xM3x10mm Fe/Zn (not countersunk head type) screws, min. class 8.8, tightened at 1Nm.
  • Page 11: Side View

    POSYC 3303 industrial PC Installation, use and maintenance manual - EN 5.3.2 Side view Ver. 1.02...
  • Page 12: Rear View (Recommended Panel Cut)

    POSYC 3303 industrial PC Installation, use and maintenance manual - EN 5.3.3 Rear view (recommended panel cut) Ver. 1.02...
  • Page 13: Hardware Features

    POSYC 3303 industrial PC Installation, use and maintenance manual - EN 5.4 Hardware features Basic Hardware 5.4.1 Processor Intel® Celeron® Quad Core N3160 (1.60GHz) Memory 4GB DDR3 1600MHz RAM CFast card 32GB Display 7 “color LED TFT, 800x480,262K colors Touch screen sensor...
  • Page 14: Order Codes

    KZ010495 5.6 Accessories The POSYC 3303 industrial PC is supplied complete with power supply connector and mass storage memo- ries. These items can also be ordered separately, like the other accessories not included in the POSYC 321X. Here is a list of the order codes:...
  • Page 15: Connections And Leds

    POSYC 3303 industrial PC Installation, use and maintenance manual - EN 6 Connections and LEDs The connectors are located in the upper part of the POSYC, as shown in the following figures. 6.1 Connections side view COM1 ETH1 ETH2 HDMI...
  • Page 16 POSYC 3303 industrial PC Installation, use and maintenance manual - EN HDD LED PWR LED Name Function PWR LED White LED signaling POSYC on HDD LED White LED signaling activity CFast Name Function CR2032 button battery slot Ver. 1.02...
  • Page 17: In Supply Connector

    Installation, use and maintenance manual - EN 6.2 24V IN supply connector The connector which powers the POSYC 3303 features spring contacts, in order to make the wiring of single cables easier. Connector type: Phoenix Contact FK-MCP 1,5/2-STF-3.81 (1851232) * **...
  • Page 18 To ensure compliance with the EMC 2014/30 / EU directive, the length of the cables must not exceed a length of 30 meters. The POSYC 3303 is a high-tech electronic device, sensitive to electrostatic discharge (ESD) phenomena. Pay the utmost attention to prevent such phenomena, complying with the pro- visions of the law, in order to avoid damage to the device.
  • Page 19: Rs485 Serial Port - Com1

    Pour garantir la conformité avec la directive EMC 2014/30 / EU, la longueur des câbles ne doit pas dépasser 30 mètres. Le POSYC 3303 est un appareil électronique de haute technologie, sensible aux phéno- mènes de décharge électrostatique (ESD). Faites très attention à ce que ces phénomènes ne se produisent pas, dans le respect des dispositions légales, afin d’endommager l’appa-...
  • Page 20: Ethernet Connectors

    POSYC 3303 industrial PC Installation, use and maintenance manual - EN 6.4 Ethernet connectors With the operating system loaded on the KE050087 memory card supplied, the two Ethernet ports ETH1 and ETH2 have different functions. Use the ETH1 connector if you want to connect the Posyc to the local network.
  • Page 21: Cfast Card Connectors

    POSYC 3303 industrial PC Installation, use and maintenance manual - EN 6.5 CFast card connectors At the bottom of the POSYC, the CFast memory card connector is instead found. The memory is secured inside the computer by blocking a lever.
  • Page 22: Installation

    Installation, use and maintenance manual - EN Installation During installation of the POSYC 3303 computer, falls and violent shocks must be avoided which could compromise the smooth operation. Avoid touching the input / output connectors on the computer panel directly unless you are equipped with suitable static electricity protection equipment;...
  • Page 23: Environmental Requirements

    POSYC 3303 industrial PC Installation, use and maintenance manual - EN 7.2 Environmental requirements The POSYC is designed to be placed in a container that gives it protection from water and dust that could dam- age it. The internal cooling of the POSYC takes place through the air sucked sideways by a high speed fan; in order for the system to work properly it must remain within the room temperature limits given in the specifications.
  • Page 24 POSYC 3303 industrial PC Installation, use and maintenance manual - EN Through appropriate repeater devices (maximum 9) it is possible to extend the connection and connect up to 126 devices. For correct operation it is necessary to use a suitable cable, terminating it appropriately. The termination consists in connecting at the beginning and at the end of the section of the re- sistors with a value of 120ohm;...
  • Page 25: Serial Signals Rs485 Port

    POSYC 3303 industrial PC Installation, use and maintenance manual - EN 7.3.2 Serial signals RS485 port The following figures show the waveforms detected by means of an oscilloscope in different connection situa- tions. Example of a correct signal Example of a signal with unfinished lines...
  • Page 26: Device Use

    POSYC 3303 industrial PC Installation, use and maintenance manual - EN 8 Device use 8.1 Touch screen The use of the POSYC computer is very similar to a normal desktop computer; the only substantial difference is the touch screen pointing device which, however, allows an even more intuitive use of the computer.
  • Page 27: Priority Of The Start-Up Devices

    8.4 Power ON When the POSYC 3303 is powered, for about 4 seconds the device will switch on and then switch off for the same period of time. Subsequently, the device will restart, with the peculiarity that the cooling fan will initially run slowly and then increase its speed until it is working.
  • Page 28: Ordinary Maintenance

    (3V lithium battery - CR2032). To replace it, simply remove the battery from its slot located at the top of POSYC 3303, then with the power off, replace the battery with a new one. To simplify the replacement, use a small screwdriver to pry it gently so that the battery protrudes slightly from its slot and then be able to grasp it easily and then pull it out.
  • Page 29: Cfast Replacement

    POSYC 3303 industrial PC Installation, use and maintenance manual - EN Pay attention to the way in which the new battery is inserted in its slot, respecting the polarity as shown in the following image: Positive polarity (+) Negative polarity (-) If the existing battery is not completely discharged, performing the replacement operation in a few seconds, it will not be necessary to correct the date / time of the CMOS Setup.
  • Page 30: Bios Update

    POSYC 3303 industrial PC Installation, use and maintenance manual - EN Then save the modified parameters in this way: • Save & Exit • Save Changes and Reset • The "Save configuration and reset ?" window opens automatically • Confirm with the "Yes" keyboard 9.4 BIOS update...
  • Page 31: Appendices

    10.1 Appendix I: CMOS Setup parameters In POSYC 3303, the CMOS Setup parameters are stored in the BIOS to guarantee operation. In the event that there is a loss of memory of the CMOS Setup, for example after the backup battery has been used up, the parameters are automatically restored when the POSYC starts up, with the exception of the date and time, which can however be reset via the operating system.
  • Page 32: Analytical Index

    POSYC 3303 industrial PC Installation, use and maintenance manual - EN 11 Analytical index Absorbed current ..........9 Panel cut ............12 Absorbed power..........9 Processor ............ 7, 13 Accessories............14 Protection degree..........9 Assembly ............6 PWR LED............16 Battery..............

Table of Contents