POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN Smitec S.p.A., viale Vittorio Veneto 4, 24016 San Pellegrino Terme (BG), Italy, www.smitec.it Installation, use and maintenance manual BEFORE STARTING UP THE POSYC 430X SERIES INDUSTRIAL PCS, CAREFULLY...
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN Summary 1 Preface ............................... 3 2 General warnings ............................4 3 Safety instructions ............................ 6 3.1 General information ..........................6 3.2 Precautions during handling and assembly ..................6 4 Product description ..........................
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN 1 Preface This manual provides all necessary information for the installation, use and maintenance of POSYC 430X se- ries industrial PCs. The instructions included in this manual are addressed to the following professionals: User is a person, a company or an institution that buys the equipment and User uses it for the purposes it was designed for.
MANUAL. THE EQUIPMENT CANNOT BE USED FOR PURPOSES DIFFERENT THAN THE ONES DESCRIBED IN THIS MANUAL; SMITEC S.p.A. SHALL NOT BE HELD RESPONSIBLE FOR ANY DAMAGES, INCON- VENIENCES OR ACCIDENTS DUE TO THE NON-COMPLIANCE WITH THESE PRESCRIPTIONS. In order to make the manual consultation easier, the following symbols have been adopted: Indication of “PROHIBITED ACTION”.
Page 5
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN The safety prescriptions aim at establishing a series of behaviors and obligations to be complied with, while performing the activities described later on in this manual. These prescriptions constitute the prescribed method of operating the device, in a way that is safe for person- nel, equipments and environment.
It is absolutely forbidden to use the equipment for different purposes than the ones de- scribed in this manual. The technical data and the drawings in this manual might have been modified later; always refer to the latest version. All upgrades can be requested to SMITEC S.p.A. directly.
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN 4 Product description The POSYC is a personal computer based on Intel®64 architecture designed primarily to facilitate human-ma- chine interfacing (HMI) in an industrial environment, but its characteristics make it suitable also for different us- es, such as information terminals and automation systems in gender.
Page 8
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN POSYC 4303 with Emkey body Rev. 1.02...
POSYC computer produced at the date of writing of this document. With the aim of improving or updating the product technologically, SMITEC S.p.A. reserves the right to change the technical features of the POSYC computer without notice.
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN 5.3 Mechanical characteristics Fixing 6 M5 threaded holes Weight 5.1 - 5.2 kg (depending on the model) 5.3.1 Mechanical dimensions 5.3.1.1 Front view Rev. 1.02...
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN 5.4 Hardware features The hardware whose features are described is the minimum guaranteed in the product and functionally tested; some peripherals possibly present in addition to the purchased product are not guaranteed neither for production continuity nor for functionality.
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN 5.4.1.1 Model POSYC 4301 "Open type UL" Basic hardware common to the POSYC 430X family 5.4.1.2 Model POSYC 4302 "Open type UL" Basic hardware (POSYC 4301) with the following additions: Profibus interface card 1 on PCI EXPRESS bus 5.4.1.3 Model POSYC 4303 "Enclosed type UL"...
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN 5.6 Accessories POSYC 430X industrial computers are supplied with power connector, mass storage and W10 IOT Enterprise license. The same can be ordered separately as well as other accessories not included in POSYC. Below is the list of order codes.
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN 6 Connections and LEDs Almost all the connectors are on the upper part of the POSYC together with the LED that indicates the presence of the 24V, as shown in the following figures. ETH1 ETH2 COM1...
Page 17
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN HDMI HDMI audio / video interface port 24V LED Green LED indicating 24V power supply presence 24V IN 24V power supply connection PROFIBUS (only POSYC 4302) Profibus card There are 2 USB connectors on the front panel and a reset button, protected by a rubber stopper, and 2 sign- aling LEDs, as shown in the following figure.
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN 6.1 24V IN connector Connector type: Phoenix Contact TVFKC 1,5/3-ST (1713842) * ** Order code: KF100038 Features Conductors cross section Connection in accordance with EN-VDE Solid min. 0,2mm² Rated voltage 250V Solid max.
Page 19
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN CAUTION Use a cable with a suitable cross-section, sized correctly according to the through-current. A cable with a section smaller than that required may cause fire due to overheating phenom- ena generated by the cable itself.
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN 6.2 RS485 serial port - COM1 Below is the pinout of the DB9 male connector on the POSYC. Serial RS485 - COM1 Signal DATA- DATA+ SHELL CABLE SCREEN SHELL Rev.
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN 6.3 RS232 serial port - COM2 Below is the pinout of the DB9 male connector on the POSYC. Serial RS232 - COM2 Signal SHELL SHELL CABLE SCREEN 6.4 Profibus card Below is the pinout of the DB9 female connector on the POSYC.
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN 6.5 Ethernet ports There are two 10/100/1000 Mbps Ethernet ports that use standard RJ45 Ethernet connectors. The two RJ45 connectors on the POSYC are shown below: Port 2 (ETH2) Port 1 (ETH1) Each of the two Ethernet ports has two LEDs.
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN 6.6 CFast card connector At the bottom of the POSYC is the connector for the CFast card. The memory is secured inside the computer via a locking lever. CFAST LOCK CFAST Bottom panel view...
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN 7 Installation During installation of the POSYC 430X computer, falls and violent shocks must be avoided which could compromise the smooth operation. Avoid touching the input / output connectors on the computer panel directly unless you are equipped with suitable static electricity protection equipment;...
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN 7.2 Assembly in dedicated body The POSYC can be mounted in one of the two dedicated aluminum frames (for the order codes see specific chapter). Both have a predisposition for the attachment to a support arm with standard dimensions and holes "VESA MIS-D, 100, T".
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN Example of assembly in a dedicated body with a push-button panel 7.3 Environmental requirements The POSYC is designed to be placed in a container that gives it protection from water and dust that could dam- age it.
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN The connection of POSYC to peripherals is simplified by the use of standard computer connectors; this means that all standard peripherals for personal computers can be connected via the cable supplied with them or in any case with easily available commercial cables.
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN Through appropriate repeater devices (maximum 9) it is possible to extend the connection and connect up to 126 devices. For correct operation it is necessary to use a suitable cable, terminating it appropriately. The termination consists in connecting at the beginning and at the end of the section of the re- sistors with a value of 120ohm;...
Page 29
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN Through appropriate repeater devices (maximum 9) it is possible to extend the connection and connect up to 126 devices. For correct operation it is necessary to use a suitable cable, terminating it appropriately. The termination consists in connecting at the beginning and at the end of the section of resistors with a defined ohmic value (see figure below);...
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN 7.4.4 Serial signals RS485 ports, Profibus DP The following figures show the waveforms detected by means of an oscilloscope in different connection situa- tions. Example of a correct signal Example of a signal with unfinished lines Example of a signal with placed terminations Example of a signal with incorrect value terminations...
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN 8 Use 8.1 Touch screen The use of the POSYC computer is very similar to a normal desktop computer; the only substantial difference is the touch screen pointing device which, however, allows an even more intuitive use of the computer. CAUTION Operate the touch screen sensor only with your fingers or soft and not sharp objects, other- wise you will damage it.
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN ATTENTION Pour éviter que les contacts des connecteurs USB situés à l'avant ne soient endommagés par l'oxydation, une fois l'utilisation terminée, protégez-les à nouveau avec le capuchon spécial pour les protéger de la poussière et de la saleté. Le capot ne garantit pas la protec- tion IP65 des connecteurs USB.
Page 33
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN For exceptional needs like backup, restore, BIOS update, etc. it is possible to start POSYC via USB flash disk (non UEFI) without having to access the CMOS setup parameters that are password protected for security rea- sons.
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN 9 Ordinary maintenance 9.1 Cleaning the touch screen sensor The cleaning of the touch-screen sensor must take place rather frequently to avoid the stratification of the dirt derived from the hands or from materials that were accidentally in contact with its surface and to maintain the best possible visibility of the display.
Page 35
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN BATTERY Battery position Rev. 1.02...
POSYC 4301/4302/4303 series industrial PCs Installation, use and maintenance manual - EN 10 Appendices 10.1 Appendix I: Parameters of the CMOS Setup In the POSYC 430X series industrial PCs, the CMOS Setup parameters are stored in the BIOS to guarantee operation.
Need help?
Do you have a question about the POSYC Series and is the answer not in the manual?
Questions and answers