3) TRANSMIT/RECEIVE DATA
(3-1) CHANNEL VOICE MESSAGES
CS6R transmits BC and A-C/1-2 of ASSIGNABLE CONTROLLER, and the data from the
Sequencer Part.
(3-1-1) NOTE OFF
STATUS
1000nnnn(8nH)
NOTE NUMBER
0kkkkkkk
VELOCITY
0vvvvvvv
Receive only.
(3-1-2) NOTE ON/OFF
STATUS
1001nnnn(9nH)
NOTE NUMBER
0kkkkkkk
VELOCITY
0vvvvvvv(v≠0)
0vvvvvvv(v=0)
(3-1-3) CONTROL CHANGE
STATUS
1011nnnn(BnH)
CONTROL NUMBER 0ccccccc
CONTROL VALUE 0vvvvvvv
* TRANSMITTED CONTROL NUMBER
c =
0
BANK SEL MSB
c = 32
BANK SEL LSB
c =
1
MODULATION
c =
5
PORTAMENTO TIME
c =
7
MAIN VOLUME
c = 10
PAN
c = 11
EXPRESSION
c = 31
EG SUSTAIN LEVEL
c = 64
SUSTAIN SWITCH
c = 65
PORTAMENTO SWITCH
c = 71
FILTER RESONANCE
c = 72
EG RELEASE TIME
c = 73
EG ATTACK TIME
c = 74
FILTER CUTOFF FREQ
c = 75
EG DECAY TIME
c = 91
REVERB SEND
c = 93
CHORUS SEND
c = 0..95
ASSIGNABLE CONTROLLER
The Sequencer Part will play back all the recorded control change messages.
* RECEIVED CONTROL NUMBER
c =
0
BANK SEL MSB
c = 32
BANK SEL LSB
c =
1
MODULATION
c =
5
PORTAMENTO TIME
c =
6
DATA ENTRY MSB
c = 38
DATA ENTRY LSB
c =
7
MAIN VOLUME
c = 10
PAN
c = 11
EXPRESSION
c = 31
EG SUSTAIN LEVEL
c = 64
SUSTAIN SWITCH
c = 65
PORTAMENTO SWITCH
c = 66
SOSTENUTO
c = 71
HARMONIC CONTENT
c = 72
EG RELEASE TIME
c = 73
EG ATTACK TIME
c = 74
BRIGHTNESS
c = 75
EG DECAY TIME
c = 91
EFFECT1 DEPTH
c = 93
EFFECT3 DEPTH
c = 96
DATA ENTRY INC
c = 97
DATA ENTRY DEC
c = 0..95
ASSIGNABLE CONTROLLER
c = 0..95
ARPEGGIO SW
c = 0..95
ARPEGGIO HOLD
*1 Used only when a value is set using RPN.
*2 Invalid with Drum Voices.
*3 Relation between BANK CHANGE and PROGRAM is as follows:
CATEGORY
----------------------------------+--------+--------+---------------------------
Normal Voice
Internal
Drum Voice
Internal
Normal Voice
Preset 1
Preset 2
Internal
External
Plug-in Voice
Plug-in 1
Plug-in 2
Drum Voice
Preset
Internal
External
Performance
Internal
External
Phrase Clip
Internal
*4 CS6x only.
*5 Transmitted/received only when MODE2 is selected in CONTROL CHANGE MODE.
*6 The default CONTROL NUMBERs of ASSIGNABLE CONTROLLER are as follows:
BREATH CONTROLLER
2
FOOT CONTROLLER
4 (Transmit: CS6x and S80 only)
SCENE CONTROL
14 (Transmit/Receive: CS6x only)
KNOB 1
16
KNOB 2
17
KNOB A
18
KNOB B
19
KNOB C
20
RIBBON CONTROLLER
22 (Transmit: CS6x only)
CONTROL SLIDER
7 (Transmit/Receive: S80 only)
FOOT SWITCH
88 (Transmit: CS6x, S80 only)
ARPEGGIO HOLD
89 (Transmit: CS6x only)
ARPEGGIO SWITCH
90 (Transmit: CS6x only)
PORTAMENTO TIME sets the time it takes for the pitch to reach the next note played
when PORTAMENTO SWITCH is set to on.
PAN position relatively changes according to the preset value for each voice.
EFFECT1 DEPTH controls reverb send level.
EFFECT3 DEPTH controls chorus send level.
HARMONIC CONTENT adjusts the resonance preset for each voice.
Setting a value adds to or subtracts from the center value, 64, since it is an offset
parameter.
The larger the value more resonant sound will be produced. The effective range may be
narrower than the range you can designate depending on the selected voice.
The parameters, EG ATTACK TIME, EG DECAY TIME, EG SUSTAIN LEVEL, EG RELEASE TIME
adjust the envelopes preset for each voice.
Setting these values add to or subtract from the center value, 64, since these are
offset parameters.
BRIGHTNESS adjusts the cutoff frequency preset for each voice.
Setting a value adds to or subtracts from the center value, 64, since it is an offset
parameter.
The smaller the value the cutoff frequency will be lowered. The effective range may be
narrower than the range you can designate depending on the selected voice.
Bank Select will be actually executed when the Program Change message is received.
Bank Select and Program Change numbers that are not supported by Yamaha will be
ignored.
n = 0 ~ 15 CHANNEL NUMBER
k = 0 (C-2) ~ 127 (G8)
ignores "v"
n = 0 ~ 15 CHANNEL NUMBER
k =
0 (C-2) ~ 127 (G8)
NOTE ON
NOTE OFF
n = 0 ~ 15 CHANNEL NUMBER
; v = 0,63,127
; v = 0,1,8,9,24,25,32,40,41,64,65
; v = 0 - 127
; v = 0 - 127
; v = 0 - 127
; v = 0 - 127
; v = 0 - 127
; v = 0:-64
-
64:0
-
127:+63 *4,*5
; v = 0,
127
; v = 0-63:OFF , 64-127:ON
; v = 0:-64
-
64:0
-
127:+63
; v = 0:-64
-
64:0
-
127:+63
; v = 0:-64
-
64:0
-
127:+63
; v = 0:-64
-
64:0
-
127:+63
; v = 0:-64
-
64:0
-
127:+63
; v = 0 - 127
; v = 0 - 127
; v = 0 - 127
; v = 0 - 127
; v = 0 - 127
; v = 0 - 127
; v = 0 - 127
; v = 0 - 127
; v = 0 - 127
; v = 0 - 127
; v = 0 - 127
; v = 0 - 127
; v = 0:-64
-
64:0
-
127:+63 *2,*5
; v = 0-63:OFF , 64-127:ON
; v = 0-63:OFF , 64-127:ON
; v = 0-63:OFF , 64-127:ON
; v = 0:-64
-
64:0
-
127:+63
; v = 0:-64
-
64:0
-
127:+63
; v = 0:-64
-
64:0
-
127:+63
; v = 0:-64
-
64:0
-
127:+63
; v = 0:-64
-
64:0
-
127:+63
; v = 0 - 127
; v = 0 - 127
; v = 127
; v = 127
; v = 0 - 127
; v = 0-63:OFF , 64-127:ON
; v = 0-63:OFF , 64-127:ON
|MSB
|LSB
|PROGRAM No
Displayed on LCD
|0
|0
|0..127
(1..128)
|127
|0
|0..1
(1..2)
|63
|0
|0..127
(1..128)
|63
|1
|0..127
(1..128)
|63
|8
|0..127
(1..128)
|63
|9
|0..127
(1..128)
|63
|24
|0..63
(1..64)
|63
|25
|0..63
(1..64)
|63
|32
|0..7
(1..8)
|63
|40
|0..1
(1..2)
|63
|41
|0..1
(1..2)
|63
|64
|0..127
(1..128)
|63
|65
|0..63
(1..64)
|63
|104
|0..3
(1..4)
(3-1-4) PROGRAM CHANGE
STATUS
1100nnnn(CnH)
PROGRAM NUMBER 0ppppppp
(3-1-5) CHANNEL AFTER TOUCH
STATUS
1101nnnn(DnH)
VALUE
0vvvvvvv
(3-1-6) PITCH BEND CHANGE
STATUS
1110nnnn(EnH)
LSB
0vvvvvvv
MSB
0vvvvvvv
Transmitted with a resolution of 7 bits.
(3-2) CHANNEL MODE MESSAGES
STATUS
1011nnnn(BnH)
CONTROL NUMBER 0ccccccc
CONTROL VALUE 0vvvvvvv
(3-2-1) ALL SOUNDS OFF
All the sounds currently played including the channel messages such as note-on and
hold-on in a certain channel are muted when receiving this message.
(3-2-2) RESET ALL CONTROLLERS (CONTROL NUMBER = 79H , DATA VALUE = 0)
Resets the values set for the following controllers.
PITCH BEND CHANGE
*3
*3
CHANNEL AFTER TOUCH
MODULATION
EXPRESSION
*4
BREATH CONTROLLER
FOOT CONTROLLER
*4
RIBBON CONTROLLER
KNOB 1
KNOB 2
SUSTAIN SWITCH
*4
SOSTENUTO SWITCH
*4
RPN
*4
*4
Doesn't reset the following data:
*4
PROGRAM CHANGE, BANK SELECT MSB/LSB, VOLUME, PAN.
*4
HARMONIC CONTENT, SUSTAIN LEVEL, RELEASE TIME, ATTACK TIME, DECAY TIME, BRIGHTNESS
*4
EFFECT SEND LEVEL 1, EFFECT SEND LEVEL 3, PORTAMENTO SWITCH
*4
PITCH BEND SENSITIVITY, FINE TUNING, COARSE TUNING
*6
ASSIGNABLE CONTROLLER
(3-2-3) ALL NOTES OFF
*3
All the notes currently set to on in certain channel(s) are muted when receiving
*3
this message. However, if Sustain or Sostenuto is on, notes will continue sounding
until these are turned off.
*2
*1
(3-2-4) OMNI MODE OFF
*1
Performs the same function as when receiving ALL NOTES OFF.
Sets VOICE RECEIVE CHANNEL to "OMNI OFF," channel 1.
(3-2-5) OMNI MODE ON
Performs the same function as when receiving ALL NOTES OFF.
*2
Sets VOICE RECEIVE CHANNEL to "OMNI ON."
*2
*2
(3-2-6) MONO
Performs the same function as when receiving ALL SOUNDS OFF. If the 3rd byte (mono)
is within 0 through 16, the channel will be Mode4(m = 1).
In VOICE MODE, the mode can be Mode2(m=1) according to VOICE RECEIVE CHANNEL.
*2
(3-2-7) POLY
Performs the same function as when receiving ALL SOUNDS OFF. The channel will be
Mode3.
*1
In VOICE MODE, the mode can be Mode1 according to VOICE RECEIVE CHANNEL.
*1
*6
(3-3) REGISTERED PARAMETER NUMBER
*6
*6
STATUS
1011nnnn(BnH)
LSB
01100100(64H)
RPN LSB
0ppppppp
MSB
01100101(65H)
RPN MSB
0qqqqqqq
DATA ENTRY MSB
00000110(06H)
DATA VALUE
0mmmmmmm
DATA ENTRY LSB
00100110(26H)
DATA VALUE
0lllllll
First, designate the parameter using RPN MSB/LSB numbers. Then, set its value with
data entry MSB/LSB.
RPN
D.ENTRY
LSB MSB MSB LSB
PARAMETER NAME DATA RANGE
00H 00H mmH ---
PITCH BEND SENSITIVITY
01H 00H mmH llH
MASTER FINE TUNE
02H 00H mmH ---
MASTER COARSE TUNE
7FH 7FH --- ---
RPN RESET
(3-4) NON-REGISTERED PARAMETER NUMBER
There are no applicable parameters.
(3-5) SYSTEM REAL TIME MESSAGES
(3-5-1) ACTIVE SENSING
STATUS
11111110(FEH)
Transmitted at every 200 msec.
Once this code is received, the instrument starts sensing. When no status nor data
is received for over approximately 350 ms, MIDI receiving buffer will be cleared,
and the sounds currently played and the sustain switch are forcibly turned off. In
this case, each control data will be reset to a certain value.
(3-6) SYSTEM EXCLUSIVE MESSAGE
(3-6-1)UNIVERSAL NON REALTIME MESSAGE
(3-6-1-1)GENERAL MIDI MODE ON
F0H 7EH 7FH 09H 01H F7H
Received only when SYSTEM Receive GM/XG on is set to on in PERFORMANCE MODE. The
Part values will be reset according to the SYSTEM Internal Part settings.
28
n = 0 ~ 15 CHANNEL NUMBER
p = 0 ~ 127
n = 0 ~ 15 CHANNEL NUMBER
v = 0 ~ 127 AFTER TOUCH VALUE
n = 0 ~ 15 CHANNEL NUMBER
PITCH BEND CHANGE LSB
PITCH BEND CHANGE MSB
n = 0 ~ 15 CHANNEL NUMBER
c = CONTROL NUMBER
v = DATA VALUE
(CONTROL NUMBER = 78H , DATA VALUE = 0)
0 (center)
0 (minimum)
0 (minimum)
127 (maximum)
127 (maximum)
127 (maximum)
0 (center)
0 (center)
0 (center)
0 (off)
0 (off)
Not assigned; No change
(CONTROL NUMBER = 7BH , DATA VALUE = 0)
(CONTROL NUMBER = 7CH , DATA VALUE = 0)
(CONTROL NUMBER = 7DH , DATA VALUE = 0)
(CONTROL NUMBER = 7EH , DATA VALUE = 0..16)
(CONTROL NUMBER = 7FH , DATA VALUE = 0)
n = 0 ~ 15 CHANNEL NUMBER
p = RPN LSB(Refer to the table as shown below)
q = RPN MSB(Refer to the table as shown below)
m = Data Value
l = Data Value
00H - 18H (0 - 24 semitones)
{mmH,llH}={00H,00H}-{40H,00H}-{7FH,7FH}
(-8192*100/8192) - 0 - (+8192*100/8192)
28H - 40H - 58H (-24 - 0 - +24 semitones)
RPN numbers will be left not designated.
The internal values are not affected.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents