Powering
Trusted Identities
Specifications
HID AERO X100
Input Voltage
Maximum Input Current
IO Module
Inputs
Output Relays
READER INTERFACE
Power
Data Inputs
OSDP (RS-485) Mode
LED Output
Beeper Output
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Humidity
MECHANICAL
Dimension
Weight
These specifications are subject to change without notice.
PLT-04234, Rev. A.3
12 to 24 V DC ±10%
1.5 A (340 mA excluding readers)
2-wire RS-485, 2,400 to 115,200 bps, asynchronous,
half-duplex, 1 start bit, 8 data bits, and 1 stop bit
Seven unsupervised/supervised, standard EOL: 1k/1kΩ, 1%, ¼ watt
(Includes TAMPER, AC FAIL, and BATT FAIL inputs)
UL evaluation for access control use only
Four relays, Form-C with dry contacts:
Normally open contact (NO): 5 A @ 30 V DC resistive
Normally closed contact (NC): 3 A @ 30 V DC resistive
12 V DC ±10%, 500 mA maximum each reader
TTL compatible, or 2-wire RS-485
9,600 to 230,400 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and 1 stop
bit. Maximum cable length: 2000 ft. (609.6 m)
Open collector, 12 V DC open circuit maximum, 40 mA sink maximum
32 to 158°F (0 to +70°C)
-67 to 185°F (-55 to +85°C)
5 to 85% RHNC
6.46" × 5.51" × 1.02" (164 mm × 140 mm × 26 mm)
342 g
HID Aero™ X100 Installation Guide
7