iLive UHP45F User Instructions, Installation, Maintenance

iLive UHP45F User Instructions, Installation, Maintenance

Advertisement

Quick Links

U s e r I n stru ct io ns , I n sta lla ti o n , ma int e n a n c e f o r
UHP45(F/FN) - UHP65(C/CN) - UHP65(D/DN - UHP75(C/CN) - UHP75(D/DN) - UHP95(PC/
PCN/FC/FCN) - UHP95(PD/PDN/FD/FDN) - UHP95(C/CN) - UHP95(D/DN) - UXLP90(F/FN)
- UXLP90(FD/FDN) - UHP1230(D/DN) - UHP125(PC/PCN/FC/FCN) - UHP125(PD/PDN/FD/
FDN) - UHF40 - UHF40N - UHF40F - UHF40FN - UHF40D - UHF40DN - UHP665 - UHP665N
- UHP665(D/DN) - UHP965 - UHP965N - UHP965F UHP965FN - UHP965(PD/PDN/FD/FDN)
- UHP9656 - UHP9656N - UHP9656(D/DN) - UHP1265-(7/7N) - HP1265(F/FN) - UHP1265-
(7D/7DN) - UHP1265(FD/FDN) - UHP765 - UHP765N - UHP765(D/DN)
cod. I/301/00/23
• C O O K T O P S •
• C O O K T O P S •
WARNING: If the information in this manual is not followed
exactly, a fine or explosion may result causing property damage,
personal injury or death.
– Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone.
Follow the gassupplier's instructions.
• If you cannot reach your gas supplier,call the fire department.
– Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
09/2014

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UHP45F and is the answer not in the manual?

Questions and answers

Summary of Contents for iLive UHP45F

  • Page 1 U s e r I n stru ct io ns , I n sta lla ti o n , ma int e n a n c e f o r • C O O K T O P S • •...
  • Page 2 IMP ORTANT - PL EASE R EAD AND FOLLOW • Before beginning, please read these instructions completely and carefully. • Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty. • Please observe all local and national codes and ordinances. • Please ensure that this product is properly grounded. • The installer should leave these instructions with the consumer who should retain for local inspector’s use and for future reference.
  • Page 3 Keeping appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids. I M P O R T A N T I N S T R U C T I O N All Appliances: Do Not Leave Children Alone - Children should not be left alone or unattended in area where appliance is in use. They should never be allowed to sit or stand on any part of the appliance.
  • Page 4 I N S T A L L A T I O N I N S T R U C T I O N S This appliance shall only be installed by an authorized person. This appliance shall be installed in accordance with the manufactures installation instructions, IMPORTANT: this appliance must be installed in accordance with the norms in force of the country concerned.
  • Page 5: Electrical Connection

    E LECT RIC A L CONN EC TIO N The g as c o o k to p re q u ire s a 120 VAC , 60H z el ec tri ca l s u p p l y to o p e ra te th e elect ro n ic i g n it io n s y s t e m.
  • Page 6: Performance Checklist

    3. F le x ib le C on n e c t ion s: 1. If the unit is to be installed with flexible couplings and/or quick disconnect fittings, the installer must use an heavy duty, AGA design-certified commercial flexible connector of at least ½”(1.3cm)ID NPT(with suitable strain relieves) in compliance with ANSI Z21.41 and Z21.69 standards.
  • Page 7 A DA PTAT IO N OF THE PRESS URE R EG UL AT O R F OR US E WI T H DI F FE RE NT TY PE O F G AS The pre s sure re g ulat o r s up pl ied w it h t he ap pl i anc e i s a c o n v e rtib le ty p e p re s s u re re g u l a t or for u se wi t h Na tur a l Ga s a t a n omi nal out l et p ressu re of 5”...
  • Page 8 CHANGING THE INJECTORS AND ADJUSTING THE AIR TAB LE 2 Bu r ner G as INP U T O RIF IC E SI M MER P RI MA RY AI R BY-PA SS R AT E S IZE RAT E O P EN IN G O RI FI CE SI Z E [B t u/h]...
  • Page 9 A1) B ur n e rs o f t he h o b 1. Remove the grill, the caps and the burners from the worktop. 2. Lift the worktop. 3. Unscrew the screw “F” and remove the pipe “R”. 4. Save the orifices removed from the appliance for future use. Unscrew the injectors (U) and replace them with those suitable for the gas used, supplied with the cooker.
  • Page 10 US ER M A NUAL IMPORTANT: keep children away from the appliance when it operates. Safety rules do not always cover any type of accident. The appliance must not be used for heating purposes. IMPORTANT: correct positioning of the brass flame distributor (d, Fig. 7) is very important. For this purpose, ensure that the flame distributor tooth (e, Fig.
  • Page 11: Surface Burners

    LI GHTI N G T HE GAS B URNERS First you have to choose the burner, through indication near the knob, then press the knob (A) controlling the desidered burner and turn it towards the left. It is important to press the knob for 10 seconds.
  • Page 12: Cooking Table

    I NSTRU CT ION S FOR USE O F T HE GA S F RY- T OP The Fry-Top is composed of a special stainless steel plate (20/64” thick), specially designed to have temperatures evenly distributed over the whole surface so that it may be exploited to the full. The plate also has hygienic advantages. Another merit is the high heat accumulation of the plate, with very low heat loss.
  • Page 13 GA S B ARB E C UE Replace the burner cap A with the protected barbecue burner cap B. Before positioning the barbecue plate, ensure that the burner cap has been fitted correctly and test lighting of the burner. To use the appliance, light the flame below the plate by means of the corresponding knob (see “Lighting the burners”) and ensure that the flame is burning.
  • Page 14: Gas C O O K Top Install Atio N

    GAS C O O K TOP INSTALL ATIO N Remove the cooktop, gas pressure regulator, burner grates and burner caps from the shipping package. Lower the cooktop into the countertop cut-out opening. Center the cooktop in the opening and check that the front edge of cooktop is parallel to the front edge of the countertop.
  • Page 15: Gas Supply Connection

    GA S S UP PLY CONNEC TIO N Assemble the flexible metal connector from the gas supply pipe to the gas pressure regulator. You will need to determine the fittings required, depending on the size of your gas supply line, flexible metal connector and shut-off valve.
  • Page 16 I NSTA LL ATI ON UH P4 5F.., UHP65. ., UHP 75.., UHP9 5 .. , UX LP 90F.., U HP123 0D.., UHP1 25.., UH F 4 0.. P roxi m i t y t o Si de Cab in et In stall atio n The cooktop may be installed directly to existing base cabinets.
  • Page 18 I NSTA LL ATI ON FOR UHP 665.., UHP765.., UH965.., UHP1 2 6 5. . A hole of 1’’ 31/32 (5 cm x 5 cm) must be done on the top for power cable and gas conduit as shown in picture The supplied feet h= 0 5/16’’(0.8 cm) must be fitted in the special holes under the hob as shown in picture...
  • Page 19 P ro xi m i ty to Side C abin et Install atio n The cooktop may be installed directly to existing base cabinets. The cooktop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36” (91.4 cm) high. For UHP965 and UHP1265 models there must be a minimum of 8”...
  • Page 22: Wiring Diagram

    W IR IN G D I AGR AM UHP4 5 F UHP65 (C/CN/D/DN) UHP75 (C/CN/D/DN) UHP95 (PC/PCN/PD/PDN/FC/FCN/FD/FDN/C/CN/D/DN) UHP1230 (D/DN) UHP125 (PC/PCN/PD/PDN/FC/FCN/FD/FDN) UHF40 – UHF40N UHF40 (F/FN/D/DN) UHP665 – UHP665D UHP965 - UHP965 (F/FD/PD/6/6D) UHP1265 (7/TD/F/FD) UHP765 - UHP765D...
  • Page 23 UXL P9 0 F - UX LP 90FD LEGEND M=Terminal board MA= Electrical ignition microswitch EL= Valve DS1= Electronic controller 00= Black 22= Red 33= White 45= Green 66= Blue K1= Earth wire terminal board N= Neutral L= Phase...
  • Page 24 E LE C T RI C AL AND GAS POW ER TAB LE...