II. RECEIPT INSPECTION
II. a - RECEIPT INSPECTION
All Traulsen products are factory tested for performance
and are free from defects when shipped. The utmost care
has been taken in crating this product to protect against
damage in transit.
You should carefully inspect your unit for damage during
delivery. If damage is detected, you should save all the
crating materials and make note on the carrier's Bill Of
Lading describing the damage. A freight claim should be
filed immediately. If damage is subsequently noted during
or immediately after installation, contact our customer care
team to file a freight claim. There is a five(5) day limit to file
freight damage with the carrier. Under no condition may a
damaged unit be returned to Traulsen without first obtaining
written permission (return authorization). You may contact
Hobart/Traulsen customer care at 800-333-7447 to request
a return or file a claim.
III. INSTALLATION
III. a - LOCATION
Select a proper location for your unit, away from extreme
heat or cold.
III. b - PACKAGING
Your Traulsen unit is shipped from the factory bolted to a
sturdy wooden pallet in stretch wrapped material.
Most exterior stainless steel surfaces have a protective
vinyl covering to prevent scratching during manufactur- ing,
shipping and installation. After the unit is installed in place
of application peel, remove and discard the covering from
all surfaces.
To remove the wooden pallet, first if at all possible, we
suggest that the cabinet remain bolted to the pallet dur- ing
all transportation to the point of final installation. The bolts
can then be removed with a 1/2" socket wrench. Avoid laying
the unit on its back for removal of the pallet.
NOTE: Traulsen does not recommend laying the unit on
its back. If you must, please allow the unit to remain in an
upright position for 24 hours before plugging it in so that the
compressor oils and refrigerant may settle.
III. c - INSTALLING LEGS OR CASTERS
Casters are installed at the factory but will require adjust-
ment upon installation.
To adjust the legs or casters, loosen the two bolts and move
leg or caster to desired location, spacing between leg or
caster not to exceed 48 inches. Leg or caster on each end of
the unit can not exceed 8 inches from the end of the cabinet.
III. INSTALLATION (continued)
III. c - INSTALLING LEGS OR CASTERS (cont'd)
III. d - CORD & PLUG:
All self-contained models are shipped standard with a
NEMA 5-15P plug and 9 foot cord . Select only a dedicated
electrical outlet for power source.
NOTE: Do not under any circumstances, cut or remove
the round grounding prong from the plug, or use an
extension cord.
III. e - POWER SUPPLY
The supply voltage should be checked prior to connection
to be certain that proper voltage for the cabinet wiring is
available (refer to the serial tag to determine correct unit
voltage, see page 1). Make connections in accordance with
local electrical codes. Use qualified electricians.
Use of a separate, dedicated circuit is required. Size wiring
to handle indicated load and provide necessary over current
protector in circuit (see amperage requirements on the unit's
serial tag).
-2-