BELL SYSTEM PRACTICES
&
AT
TCo Standard
636CA, 636CAM, 637DA, AND 637DAM TELEPHONE SETS
1.
GENERAL
This section contains connection and maintenance
1.01
information for 636CA (MD), CAM (18-button)
and 637DA (MD), DAM (30-button) CALL DIRECTOR®
telephone sets equipped with headset jacks.
This section is reissued to:
1.02
Add information on 636CAM and 637DAM
(modular) telephone sets, Fig. 1
Show the 636CA and 637DA telephone set
MD.
2.
CONNECTIONS
These sets are factory-wired for use with
2.01
1A1, 1A2, or 6A KTS line circuits.
may also be used with 1A KTS line circuits by
modifying the set as shown in Table A and B.
Line circuits for 1A, 1A1, or 1A2 KTS may be
connected to the same set under the following
conditions:
(a) 1A1 or 1A2 KTS lines must be connected
to the first key units with 1A lines connected
to supplementary key modules.
(b) 1A, 1A1, or 1A2 KTS lines should not be
connected to the same 6 line key module.
(c) 1A, 1A1, or 1A2 KTS lines appearing behind
a
manual
switchboard
intermixed on a CALL DIRECTOR telephone set
due to the different time out intervals provided
by the associated KTU's.
The 636CA, CAM and 637DA, DAM sets are
2.02
equipped with a 635A5C (5-line pickup and
hold) or 635AD5C (4-line pickup, cutoff, and hold)
key in the first module position.
assemblies [required with sets equipped with a
Dl20K (MD) or D200S (MD) mounting cord] differ
SERVICE
between the
replacement, the 635AD5C is furnished with a
piggy-back adapter to which the slate mounting
cord plug is connected. The necessary contact strip
assemblies (840151039 and 840151047) will be shipped
with the 635AD5C key, and will replace the 840151120
and 840151138 assemblies supplied with the 635A5C
key.
2.03
to the chaining switch. This requires a second tip
and ring to each module (except the last).
Fig. 2, sheets 1 through 5.
2.04
to the rear of the keys. This permits rearrangement
They
of line appearance either in the set or at the key
equipment distribution point.
sets are equipped with a satin-silver (-87) mounting
cord.
2.05
by removing the .812857738• (P-28E773) screw
detail from key positions involved and making the
necessary wiring changes per Table C.
2.06
2.07
should
n o t
be
(10 volt AC only) buzzer.
2.08
circuits, there are two optional circuits available.
The busy lamp(s) will light whenever a line pickup
button is depressed and the handset is off-hook or
the headset is plugged into the jacks. This optional
Contact strip
equipment must be ordered separately.
than one busy lamp is required, a 6C KTU must
NOTICE
Not for use or disclosure outside the
Bell System except under written agreement
Printed in U.S.A.
SECTION S02-61 0-418
two keys.
If ordered for field
Because of the physical arrangement of the
635-type key, the contact strips do not extend
Mounting cords of these CALL DIRECTOR
sets terminate in individual plugs connected
All line key positions are convertible to
signaling or common signaling arrangements
These sets are not intended for use with
speakerphone systems.
The 636CA, CAM and 637DA, DAM telephone
sets are factory-equipped with a KS-20419L1
When station busy lamp feature is required
with these sets having 1A1 or 1A2 KTS line
Issue 5, April 1976
See
Current production
If more
Page 1

Advertisement

loading

Summary of Contents for AT&T 636CA

  • Page 1 When station busy lamp feature is required by the associated KTU's. 2.08 with these sets having 1A1 or 1A2 KTS line The 636CA, CAM and 637DA, DAM sets are circuits, there are two optional circuits available. 2.02 The busy lamp(s) will light whenever a line pickup...
  • Page 2: Maintenance

    SECTION 502-61 0-418 be connected as shown in Fig. 5. For a single (2) Disconnect all mounting cord plugs and the busy lamp, install a D-180463 Kit of Parts (ordered two contact strips [sets equipped with D120K separately), consisting of a •819040338• (P-90D033) (MD) or D200S (MD) mounting cords] from the Printed Wiring Board Assembly and 840361836 plug second module, remove key and replace with...
  • Page 3 TERM BOARD OR 4228-1YPE NET�DRK 2418 AMPLIFIER 40108 Fig. 1-.636CA, CAM and 637DA, DAM Telephone Set, Connections. Page 3 05, Ol2 16:24 : } 3 !!_ 8 sse 5_02-610318-c0_5_191_6-0 4-0_3�iRg Scannea by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Oct...
  • Page 4 SECTION 502-610-418 Notes for Fig. 2: I. THE 635ADSC KEY IS SUPPLIED \liTH AN ADAPTER IN THE CUTOFF KEY POSITION. THE SLATE MOUNTING CORD PLUG CONNECTS TO THE ADAPTER, CONNECT BL-Y Y-BL ADAPTER LEADS TO TERMINALS I AND 2, RESPECTIVELY. BALANCE OF PLUGS CONNECT DIRECTLY TO KEY. 2.
  • Page 5 DI20K,M CAM OR MODULE 636CA. 637DA� OR 0200S,AA. A75A OR A 1000 TO riG. CONN(CTOR CABLE MOUNT I NG CORD S·Y (Bl-W) BINDER CONN {0-B Kl ! (NOTE 63 5 AOSC R OR Rl � ( C ) -;; 5 � - �- ( G) �:...
  • Page 6 V-Bl � � -t:=:::b ACAN T BL•V � ;J� � � IO OD � > � � � � � rROM 3-6370A, DAM TO SH 5-636CA, CAM Fig. 2-Module and Connector Cable Arrangements (Sheet 2 of 5) OS, 2012 16:25:36...
  • Page 7 41000 CONNECTOR CJ.Illf (C.-W) FROM SH 2 02005 0200AA CORD (G I MOUNTING INOTE7) � COHN 3 BINDER 6370A, DAM 3RO MOOULE PLUG 3 (BA-Y) PARE SPARE 635GSC SPARE BL-Y (Y-BL) (Y-BL) PICKUP G-BK (BK-G) PICKUP BR-BK " BK-BR S•BK BK-S S·R (R-S)
  • Page 8 A 1000 CONNECTOR 4TH MODULE 6370A, CABL[ � (BR-W) BINDER PLUG 4 FROM SH 3 02005 OR 0200AA {BR- Y) SPARE MOUNTING CORD SPAR[ {BR) BINDER SPAR( CONN . . fk 5GSC ,c:; ___ -·�·'.2... _____ ,:::c, _ Y•S SPARE ., ..
  • Page 9 { R ) R ( S) OR r---c\ 5 C O N N 3 CORD 0120K OR DI20M G T ( 5 l OR MODULE 636CA, CAM Ofll 0200AA 02005 (NOTE 7} PLUG ( R ) ( G ) N O T £ Z - - - - - -;r:.,_ "1:...
  • Page 10 SECTION 502-61 0-418 819040338 ( P - 90D033) PRINTED WIRING BOARD ASSY P/0 D -18046 KIT OF PARTS (o-w) (Y)+ (BR) (O-W) (0-BK) (W-0) (BK); (o)! § § ( V-G) (G-V) 51 A (BL); LAMP ( Y-BR) -24V 44 ) LEGEND: NOTE: A SINGLE...
  • Page 11 ISS 5, SECTION 502-610-418 1ST HOLD (O-Wl (W-0) !0-B KI § (W-0) t (Y-BRI � I >--+-< 2 2ND HOLD 20 (G-V) �6>-+-<5 INSULATED AND STORED USE D-161488 CONNECTOR OR S PARE TERMIN A L LEA D S INVOLVED I N MODIFICATION FROM (0) BINDER LINE SWITCH...
  • Page 12 SECTION 502-610-418 TABLE B 1A, 1A 1, AND 1A2 CONVERSION-637-TYPE TELEPHONE SET LEAD LINE CONTACT STRIP HOLD KEY CHAINING PLUG MODULE OR PLUG ARRANGE• MENT BR-V V-BR 1A1/1A2 • • Only 1A1/1A2- 1st, 2nd, 3rd, 4th, Mod 1A-5th Mod 1A1/1A2- 1st, 2nd, 3rd Mod 1A-4th, 5th...
  • Page 13 If more than six signal keys are required, replace 635G5C key with a 658A key. more than five private or intercom lines are required, convert keys in 2nd (636CA, CAM) or 4th (637DA, DAM) module in same order. Connect plug leads to terminal 39 to utilize common signal key.
  • Page 14 SECTION 502-61 0-418 TABLE .D CUT OFF KEY (635AD5C) CONNECTIONS 635AD5C MOUNTING CONNECTOR CABLE CORD RINGER PLACE FEATURE (BL-W) BINDER ADAPTER (BL) BINDER STRAP BL-Y Y-BL BL·Y Y-BL G-BK BK-G BK-BR Cutoff Ringer in TB1-1 TB1-2 Note 2 TB1·1 (Not.) Set (Note 1) TB1-2 Cutoff Ext...

This manual is also suitable for:

636cam637da637dam