Connections; Power Connections - dallmeier Domera DJB-115W Installation Manual

Junction box, outdoor mounting accessories
Table of Contents

Advertisement

Outdoor Mounting Accessories – Junction Box DJB-115W
6

Connections

The connection and commissioning of the unit may only be carried out by qualified per-
sonnel.
6.1

Power Connections

AC INPUT
 First, set the correct AC mains power voltage suitable for your country (115 V or 230 V)
before connecting the AC mains power to the AC input terminal.
 Next, connect the protective earthing conductor to the AC input terminal labelled with
"PE" (protective earth).
 Then, connect the AC live wire (phase conductor) to the AC input terminal labelled
with "L" (live wire) and the AC neutral wire (return conductor) to the AC input terminal
labelled with "N" (neutral wire).
 Finally, connect the camera and/or other equipment (e.g. heater of weather-proof hous-
ing) to the AC output terminal.
22
DANGeR
electric shock hazard
Danger of death or serious injury
 Disconnect the power supply unit from the mains socket before con-
necting or disconnecting the device or ensure that the AC mains power
outside the device is switched OFF.
115
115
230
115V/230V
SWITCH
PoE
AL1
AL5
AL2
AL6
AL3
AL7
AL4
AL8
GND
GND
COM
COM
NC1
NC2
NO1
NO2
PoE
PoE+2
AL1
AL5
PoE+1
AL2
AL6
RX−
AL3
AL7
PoE−2
AL4
AL8
PoE−1
GND
GND
RX+
COM
COM
TX−
NC1
NC2
TX+
NO1
NO2
Fig. 6-1: Power connections
OUT 3
RX+
RX−
Line IN
TX+
TX−
RS485
Line OUT
OUT R
OUT L
OUT GND
IN R
IN L
IN GND
www.dallmeier.com
OUT 1
OUT 2
AC OUTPUT