PCD2.H110
7. Error handling and diagnosis
7.1 Definition errors checked by the assembler
The following definition errors in file D2H110_b.MBA are checked
during assembly:
• If the number of modules (NbrModules) is lower than 1, no code is
"Remark : No H110 used (NbrModules = 0 in D2H110_B.MBA)"
• If the number of modules (NbrModules) is greater than 16, no code is
"Error : more than 16 Modules H110 defined (NbrModules = 0...16)"
• If an incorrect instruction code is used for FB 'Exec' (e.g. RdIdenti
"Symbol not defined 'H110.RdIdenti'"
(generating the printout 'H110' from $group h110)
• If the definition $group H110 is absent, then for each instruction and
"Symbol not defined"
26/755 E2
(2H1-70-E.DOC)
assembled and the following warning is displayed in the 'Make'
window:
assembled and the following error message is displayed in the 'Make'
window:
instead of RdIdent), the assembler reports an error:
each register/flag used in the program the assembler reports:
SAIA-Burgess Electronics Ltd.
Error handling and diagnosis
Page 7-1