COMMISSIONING AND MAINTENANCE
REPLACING THE CPC REFLECTOR
Our CPC reflectors are manufactured and delivered under the
best possible conditions.
Nevertheless, if a fault (e.g. a large dent) is found, they can be
replaced quickly and easily.
Proceed as follows, taking all the necessary precautions, to re-
move a damaged reflector:
− Unscrew and remove the plug (1) from the foot of the col-
lector
− Remove the bracket (2) into which the plug was screwed
by bending back the clips (3)
− Remove the reflector (4) without moving its glass tube.
1
2
15
4
4
3