TRANSPORTING THE MIST BLOWER
Please keep the mist blower in an upright position whenever transporting or storing.
Transporting or storing in a position that is not upright may cause oil to spill inside the
mist blower engine. This may result in oil leaks and white smoke from burning oil, and
the air cleaner may become dirty with oil.
DANGER:
When transporting and storing the mist blower, be sure to stop the engine.
Draining and cleaning the solution tank
WARNING:
Always wear rubber/chemical-resistant gloves when cleaning and draining the solution tank.
Draining the solution tank
WARNING:
Never dispose chemical or rinsed water by opening the cap
at the bottom of the solution tank.
Before and after draining, make sure that the solution
discharge lever is closed.
If chemical solution is still remained in the solution tank
after the method mentioned in the instruction manual, tilt
the machine towards pipe side to pour out all the remained
solution.
1. Put the mist blower onto a stable place. Position the nozzle
(1) lower than the bottom of solution tank (2), and place a
receiving container beneath it.
2. Set the knob (3) to the position E.
3. Open the solution tank cap (4) slightly to release pressure of the tank.
4. Open the solution discharge lever (5). Chemical solution is discharged from the nozzle.
5. Clean the tank inside with water.
Cleaning the strainer of solution tank
Remove the tank cap, take out the strainer from inside the tank and then clean it
after use.
(3)
(1)
22
(5)
(4)