8. SPECIFICATIONS

MATERIALS
Bolt Pin
Lock / Strike Plate
MECHANICAL
Cycle life
Max Strike Gap
Holding Force
ELECTRICAL
Voltage at Lock
Current Usage
Monitor Switches
CERTIFICATIONS
FCC
CE

9. MAINTENANCE AND INSPECTION

The YD25K has been lubricated at assembly and applying any other type of lubricant may void the warranty. With
the cover removed it is important to take care when selecting the dip switch positions. A dry cloth can be used to
polish the stainless steel face plate and strike plate as required. This lock contains components that are subject to
wear based on usage, doorway operation and installation; all such factors are beyond the control and measurement
of the manufacturer. The lock may be vulnerable and subject to failure as a consequence of wear and as its
components near the end of the period of normal usage.
It is the responsibility of the owner/end-user to:
a) Ensure that the lock is installed in accordance with the instructions set out in these guidelines.
b) Determine the suitability of this lock for the application intended and in particular when using this lock in
critical applications such as on fire, high security, safety, or emergency exit doors.
c) Regularly inspect this lock in order to assess signs of wear and tear, and determine if the operation still
conforms to the instructions set out in these guidelines.
d) Regularly inspect the lock and evaluate cycle life.
e) Determine when this lock should be replaced.
Page 12
Stainless Steel (SS304), ø12.7mm, 16mm Extension
Stainless Steel (SS304), 3mm Thick
1,000,000
6mm
10,000N (1000kg)
12 – 24VDC ±15%
Max Holding Current
Max Operating Current
Bolt position – 25VDC, 0.5A
Door position – 100VDC, 0.5A
Part 15 Subparts A & B – Unintentional Radiators
EMC 2014/30/EU
RoHS 2011/65/EU
MD 2006/42/EC
160mA@12V
95mA@24V
1250mA@12V
1000mA@24V
EN 61000-6-1:2007
EN 61000-6-3:2007+A1:2011
RoHS 2 Compliant
EN ISO 12100:2010
MP001156.004