8. SPECIFICATIONS

MATERIALS
Bolt Pins
Strike Plate
Lock Face Plate
MECHANICAL
Cycle life
Strike Gap
Holding Force
Side Load Release
Door Misalignment
ELECTRICAL
Voltage at Lock
Current Usage
Monitor Switches
CERTIFICATIONS
Patent
FCC
CE
*
Initial power up of the lock requires up to 1800mA@12VDC and up to 600mA@24VDC for up to 6 seconds but only occurs
when the power has been completely removed for an extended period then re-applied, for example after a power outage.
Normal Operating Current after initial power up is <250mA@12VDC and <200mA@24VDC.

9. MAINTENANCE

The COBALT has been lubricated at assembly and applying any other type of lubricant may void the warranty.
Removing the lock cover may void the warranty. A dry cloth can be used to polish the stainless steel face plate and
strike plate as required.

10. WARRANTY

The COBALT is covered with a manufacturers 12month warranty against faulty or malfunctioning parts,
components or product. At the manufacturer's discretion, either a replacement lock or affected part will be supplied
to remedy the fault or the lock can be returned at the customer's expense to the manufacturer for repair.
Mistreatment or ill-use of the lock may void the warranty. COBALT is a trademark of BQT Solutions (SEA) Pte
Limited. BQT Solutions (SEA) Pte Limited will not be liable for any direct, indirect, incidental or consequential loss
or damage in any way related to this product.

11. UPGRADE

The COBALT is designed by BQT Solutions (SEA) Pte Limited and manufactured by BQT Solutions (NZ) Limited.
BQT Solutions (SEA) Pte Limited reserves the right to upgrade or change this product without prior notice.
For more information visit www.bqtsolutions.com
© BQT Solutions (SEA) Pte Limited
SS17-4PH, 10mm Thick, 13mm extension (2 Pieces)
SS304, 3mm Thick
SS304, 3mm Thick
> 300,000
< 7mm
> 10,000N (1000kg)
> 1,000N (100kg)
+/- 8mm
12 – 24VDC ±15%
Holding Current
Operating Current
Initial Power Up*
Bolt position – 30VDC, 0.1A
Door position – 100VDC, 0.5A
Pending PCT/IB2013/053737
Part 15 Subparts A & B – Unintentional Radiators
EN 61000-6-1: 2007, EMC Directive 2001/108/EC Immunity
EN 61000-6-3: 2007, EMC Directive 2001/108/EC Emissions
< 50mA@12V
< 30mA@24V
< 250mA@12V
< 200mA@24V
< 1800mA@12V
< 600mA@24V
Page 10