b) Connecting power supply
Connect the protective-earth
lead for load
conductor to the earth
The power supply lead to
terminal (
the light is also a 2 - 3-core
7. Screw on enclosure and
cable. Connect the light's
re-close.
live conductor to the terminal
8. Fit sensor lens (reach
marked L'. Connect the
either 8 m or 20 m max.),
neutral conductor to the
see section on setting reach.
terminal marked N together
with the mains power supply
lead's neutral conductor.
Installing corner wall mount
Functions
Once you have connected the
to put the system into opera-
unit to the mains power sup-
tion. Two setting options are
ply, closed the housing and
concealed behind the design-
fi tted the lens, you are ready
er front trim
Twilight setting (response threshold)
(Factory setting: daylight operation 2000 lux)
The sensor's response threshold can be infi nitely varied from
2 – 2000 lux.
Control dial set to
2000 lux.
Control dial set to
To adjust the detection zone in daylight, the control dial must
2 – 2000 lux
be set to
Switch-OFF delay (time setting)
(factory setting: 5 sec.)
Light ON duration can be infi nitely varied from 5 sec. to
15 min.
Control dial turned fully anticlockwise) = shortest time (5 sec.)
Control dial turned fully clockwise = longest time (15 min.)
When setting the detection zone, it is recommended to select
the shortest time (dial turned fully anticlockwise).
5 sec. – 15. min.
9. Select time setting
and twilight setting
).
(see 'Functions').
10. Fit designer front trim
and secure in place with
lock screw
to prevent
unauthorised removal.
Important: Reversing the
connections may result in
damage to the unit.
The corner wall mounts
provided with the unit make it
easy to install the IS 2180-5
on internal and external
corners. Use the corner wall
mount as a template for
drilling holes. This way, you
will drill the hole at the right
angle, allowing you to fi t the
wall mount with ease.
Important: Only select time
and twilight setting with the
lens in place.
.
= daylight operation at approx.
= twilight operation at approx. 2 lux.
(daylight operation).
16
Manual override function
If a mains switch is installed
Important:
in the mains supply lead,
The switch should be
the following functions are
actuated in rapid succession
provided in addition to simply
(in the 0.5 –1 sec. range).
switching light ON and OFF:
1 x OFF/ON
5 sec. - 15 min.
2 x OFF/ON
Sensor mode
1) Switch light ON:
Switch OFF and ON once.
Light stays on for the period
selected.
2) Switch light OFF:
Switch OFF and ON once.
Light goes out or switches to
sensor mode.
3) Manual override:
Turn switch OFF and ON
twice. The light is set to stay
ON permanently for 4 hours
(LED - below the lens - lights
up) and then automatical-
ly returns to sensor mode
(LED OFF).
Manual override can also be
deactivated during the 4-hour
period by switching OFF and
back ON again. The light then
returns to sensor mode.
4 hours