BNC
To connect data cabling for the 8 way cage clamp terminal block, strip the wire between 8mm to 12mm
in length. Insert the cable into the appropriate slot. Using a flat head screw driver, push the orange latch
that is above the cable being inserted and push the cable further in. Release the orange latch. Gently
pull the cable to ensure it is connected and does not come out. If it does come out, the wire is not
stripped enough. Note that if the wire is stripped less than 7mm, there will not be a secure connection.
Shielded cables are recommended for video and data wiring.
8 –12mm
Data Cabling
PAGE 11
OPTICAL SYSTEMS DESIGN
FIGURE 3: DATA CONNECTOR PINOUTS
FIGURE 4: DATA CABLING CONNECTIONS
OSD8826 OPERATOR MANUAL
8 Way Cage Clamp Data Connector
8 7 6 5 4 3 2 1
Power Connector
Power Connector
8 Way Cage Clamp Data Connector
Push
Insert
RJ45 Connector
8 7 6 5 4 3 2 1
DOC ID: 10110306