Panasonic CS-C18JKV Service Manual page 37

Hide thumbs Also See for CS-C18JKV:
Table of Contents

Advertisement

• Dirtiness level sensitivity adjustment.
It is possible to change the Patrol sensor sensitivity, where the Threshold value (G1 ~ G4) will be shifted accordingly:
1. Press and release "SET" button.
2. Press "Timer
" / "Timer
(Air 1"Low Sensitivity" <
3. Confirm setting by pressing "Timer Set" button. LCD returned to original display after 2 seconds.
4. LCD returned to original display if remote control does not operate for 30 seconds.
• e-ion Control
- e-ion operation starts condition
- When dirtiness at level 2 (Patrol LED turns red).
- 2 minutes after stabilization time (Patrol LED turns red).
- 4 hours at level 0 (Patrol LED turns red).
- e-ion operation time
- If dirtiness level improves from level 2 to level 1 (Patrol LED from red to orange), the unit carries out level change after 60
seconds.
- When dirtiness level returns to level 0 (Patrol LED turns blue) continuously for 11 minutes or more, e-ion operation stops.
• Dirtiness Level and fan speed
- When e-ion operation starts, the fan speed increases based on dirtiness level:
- Indoor Fan Control
- During any operation mode combines with Patrol operation, fan speed follows respective operation mode.
- During Patrol individual operation if e-ion starts, only Auto Fan Speed and no Powerful operation is allowed. Even if "Fan
Speed" button is pressed, no signal is sent to air conditioner, and no change on LCD display.
- During Patrol individual operation if e-ion stops, Indoor Fan stop operation.
- Airflow direction (Horizontal, Vertical) Control
- During any operation mode combines with Patrol operation, airflow direction follows respective operation mode.
- During Patrol individual operation if e-ion starts, only Auto Air Swing is allowed. Even if "Air Swing" button is pressed, no
signal is sent to air conditioner, and no change on LCD display.
- During Patrol individual operation if e-ion stops, Airflow direction louver closed.
- Indicator
- When Patrol operation starts, Patrol LED is ON with 3 different colors:
- Then e-ion operation starts based on dirtiness level, both Patrol LED and e-ion LED are ON.
" button to select sensitivity.
> Air 2 "Standard" (Default) <
Patrol LED
Blue
Orange
Red
> Air 3 "High Sensitivity")
Air Quality
Clean
Moderate
Dirty
37