ET4001 Crimp machine WARNING WARNING Eaton's hose and Eaton hose fittings should only be assembled Failure to follow Eaton processes and product instructions and using Eaton approved assembly equipment. Do not use any limitations could lead to premature hose assembly failures, combinations of Eaton's hose, Eaton hose fittings, or Eaton resulting in property damage, serious injury, or death.
Page 3
ET4001P-002 Electric pump The Eaton ET4001P-002 power unit is ideally suited for use with the ET4001 press. It features a two-stage pump providing high flow at low pressure for fast ram approach and low flow at high pressure for actual crimping.
Page 4
90º IT IS RECOMMENDED elbow fitting (Figure 5). THAT THE PUMP BE ON AN INDIVIDUAL 20 AMP SERVICE OUTLET. EATON ET4001 Crimp machine operator´s manual W-EQCR-TM022-E3 March 2019...
Page 5
6. REPEAT STEPS 3 & 5 APPROXIMATELY SIX TIMES. This will purge the hydraulic system. WARNING Do not attempt to disconnect the hose sssemblies when the pusher is not fully retracted. EATON ET4001 Crimp machine operator´s manual W-EQCR-TM022-E3 March 2019...
Page 6
PTFE return the pusher. OPEN based lubricant (T-400-G). the pusher halves and remove the crimped hose fittings. 6. Visually inspect the crimp and verify the correct crimp diameter and crimp length. EATON ET4001 Crimp machine operator´s manual W-EQCR-TM022-E3 March 2019...
Page 7
PTFE-based return the pusher. OPEN lubricant (T-400-G). the pusher halves and remove the crimped hose assembly. 11. Visually inspect the crimp and verify the correct crimp diameter and crimp length. EATON ET4001 Crimp machine operator´s manual W-EQCR-TM022-E3 March 2019...
Page 8
Move the switch to the RETRACT position to return the pusher. OPEN the pusher halves and remove the crimped hose fittings. 6. Visually inspect the crimp and verify the correct crimp diameter and crimp length. EATON ET4001 Crimp machine operator´s manual W-EQCR-TM022-E3 March 2019...
Page 9
= Remove old grease and re-lubricate Base adapter ring lubrication Every 250 crimps = Remove old grease and re-lubricate Every 1,000 crimps = Remove old grease, inspect for wear or damage and re-lubricate if okay. EATON ET4001 Crimp machine operator´s manual W-EQCR-TM022-E3 March 2019...
Page 10
Having unit operate at crimping psi too long; Operate for 3 seconds at crimp pressure; Low oil level: Step #2, Pump worn (longer cycle time); Replace pump, Leaking relief valve and /or shuttle valve Step #3, #4 EATON ET4001 Crimp machine operator´s manual W-EQCR-TM022-E3 March 2019...
Page 11
Base adapter ring ET4000AR-002 Base adapter ring ET4000TP-0001 Locator bracket kit ET4000TP-0002 Wear plate kit ET4001C-0015 Blue shroud 120-00429 Screw, hex head ET40014-006* Left ET40015-006* Right * must be ordered as a pair EATON ET4001 Crimp machine operator´s manual W-EQCR-TM022-E3 March 2019...