Toshiba MMU-AP0057MH-E Installation Manual page 19

Air conditioner (multi type), indoor unit
Hide thumbs Also See for MMU-AP0057MH-E:
Table of Contents

Advertisement

 Selecting swing type
1. Push
for 4 seconds or more when the air
conditioner is not working.
flashes.
Indicates CODE No. [F0].
2. Select an indoor unit to be set by pushing
(left side of the button).
Each time you push the button, unit numbers
change as follows:
UNIT No.
UNIT No.
UNIT No.
1-1
1-2
1-3
No
UNIT No.
display
1-4
The fan of the selected unit runs and the louvers
start swinging.
3. Select a swing type by pushing "TIME"
buttons.
Swing SET DATA
Swing SET DATA
Swing of louvers
Standard swing
0001
(Factory default)
0002
Dual swing
0003
Cycle swing
CAUTION
CAUTION
Do not set the swing SET DATA to "0000".
(This setting may cause a failure of the louvers.)
35-EN
• About "Dual swing"
"Dual" means that louvers 01 and 03 are directed
and swing in one direction and louvers 02 and 04 are
directed and swing in the opposite direction.
(When louvers 01 and 03 are directed downward,
louvers 02 and 04 are directed horizontally.)
• About "Cycle swing"
The four louvers swing independently at respective
timings.
03
04
02
01
Drain pipe
Refrigerant pipe
4. Push
button.
5. Push
button to complete the setting.
 Locking the louvers
(No swing)
1. Push
(right side of the button) for 4 seconds
or more when the air conditioner is not working.
flashes.
Indicates CODE No. [F1].
2. Select an indoor unit to be set by pushing
(left side of the button).
Each time you push the button, unit numbers
change as follows:
The fan of the selected unit runs and the louvers
start swinging.
UNIT No.
UNIT No.
UNIT No.
1-1
1-2
1-3
UNIT No.
1-4
3. Select a louver you want to lock by pushing "TEMP."
buttons.
4. Select the wind direction of the louver you do not
want to swing by pushing "TIME"
(1)
(2)
SET DATA
0001
0002
0003
(4)
(5)
0004
0005
* When (4) or (5) is selected, dew drop may occur
during cooling mode.
5. Determine the setting by pushing
When the setting has been determined,
up.
6. Push
button to complete the setting.
0001-0005
(Louver lock position code)
– 18 –
 Cancelling louver lock
Set the wind direction to "0000" of the louver lock setup
procedure above.
Setting data
0000
• When the setting is canceled,
Other operations are the same as those in
"Locking the louvers (No swing)".
 Remote controller sensor
The temperature sensor of the indoor unit senses room
temperature usually. Set the remote controller sensor
to sense the temperature around the remote controller.
Select items following the basic operation procedure
1
2
3
4
5
6
(
).
buttons.
• Specify [32] for the CODE No. in Procedure
• Select the following data for the SET DATA in
4
Procedure
.
(3)
SET DATA
0000
Remote controller
Not used
sensor
(Factory default)
When
flashes, the remote controller sensor is
defective.
Select the SET DATA [0000] (not used) or replace the
remote controller.
button.
 Group control
lights
In a group control, a remote controller can control up to
maximum 8 units.
• The wired remote controller only can control a group
control. The wireless remote controller is unavailable
for this control.
• For wiring procedure and wires of the individual line
(Identical refrigerant line) system, refer to "Electrical
Connection" in this Manual.
• Wiring between indoor units in a group is performed
in the following procedure.
• Connect the indoor units by connecting the remote
controller wires from the remote controller terminal
blocks (A, B) of the indoor unit connected with a
remote controller to the remote controller terminal
blocks (A, B) of the other indoor unit. (Non-polarity)
• For address setup, refer to the Installation Manual
attached to the outdoor unit.
goes out.
3
.
0001
Used