Download Print this page

µ-Dimension mDB-2500.1D Comp Owner's Manual page 3

Advertisement

2. DESIGN FEATURES
2-1. Digital-series amplifiers are working fully stable down to 4/2/1 ohm as single unit.
Daisy Chain connection makes it fully stable down to 2 ohm and double 1 ohm power of
single unit.
2-2. Digital-series amplifiers have the possible highest efficiency and sufficient amount of
the components which maximize the performance.
2-3. Digital-series amplifiers have 4 ways of acurate protection circuitry, as speaker short,
DC offset, voltage ( High and Low ), thermal protection which are the most safe-guard.
μDB-2500.1D Comp
μDB-5000.1D Comp
2-4. Digital-series are designed in double sided board (
μDB-5000.1D Comp
2-5. Digital-series have 24dB/Oct slope of crossover, Low Pass Filter and Subsonic Filter ,
as fully adjustable.
2-6. Digital-series amplifiers have dash mount remote level control which allows very
convenient level control from the driver seat.
2-7. Digital-series amplifiers have daisy chain connection which makes 2 units of
Digital-series amplifiers bridged into 2 ohm and produce the highest output power.
3. CONTROL & CONNECTION
3-1. CONTROL & CONNECTION
INPUT
Connect preamp signal cables from the head
unit to RCA Input.
OUTPUT
Output Rca jack to another amplifier.
POWER & PROTECTION INDICATOR
Power LED, Blue-lit shows correct operation.
Protect LED, RED-lit shows general malfunction,
faulty connection and thermal protection.
GAIN
Matching the output voltage of the headunit's
RCA line-outs to input section.
Its range is 9V to 0.2V.
voltage protection range is 8.5V ~ 16V,
voltage protection range is 8.5V ~ 18V .
- 3 oz copper ) and use high current mosfet swtiching devices.
μDB-2500.1D Comp
SUBSONIC CROSSOVER FREQUENCY
Control the high Pass point for the speaker
outputs to eliminate extreme low frequencies.
Its range is 10~ 50 Hz @ 24dB/Oct.
BASS BOOST
It controls boost from 0 ~ 9dB at 45Hz
REMOTE LEVEL CONTROL PORT
This port is for connecting remote level control.
Remote level control adjusts the level
LPF CROSSOVER FREQUENCY
Controls the low pass point for the speaker outputs.
The crossover range is 35~250Hz @ 24dB/oct
PHASE
Variable phase adjustment range is from 0 to 180
degree.
- 2 oz,

Advertisement

loading

This manual is also suitable for:

Mdb-5000.1d comp