Download Print this page

Operation - Hilti TE 3000-AVR Original Operating Instructions

Hide thumbs Also See for TE 3000-AVR:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 16

5 Operation

5.1 Preparations at the workplace
CAUTION
Risk of injury! Inadvertent starting of the product.
▶ Unplug the supply cord before making adjustments to the power tool or before changing
accessories.
Observe the safety instructions and warnings in this documentation and on the product.
5.1.1 Fitting the accessory tool
Note
Check the accessory tool for damage or uneven wear each time before use and replace it if necessary.
Check that the locking bar is clean and undamaged.
1. Apply a little grease to the connection end of the accessory tool.
2. Open the locking bar.
3. Push the accessory tool into the chuck as far as it will go.
4. For accessory tools with a collar, bring the retaining bar into locking position A.
5. For accessory tools with a locking groove, bring the retaining bar into locking position B.
◁ Position the chisel so that the groove is facing locking position B.
6. Check that the chisel has engaged correctly by gripping and pulling it.
◁ Insert tools with a combined connection end (with collar and groove) can be locked in position A or
B, as desired.
Note
Use only the recommended grease supplied by Hilti. Use of unsuitable grease may cause damage
to the product.
5.1.2 Removing the accessory tool
WARNING
Risk of injury! The accessory tool gets hot during use and may also have sharp edges.
▶ Wear protective gloves when changing the tool.
DANGER
Risk of fire! Risk of contact between the hot accessory tool and highly inflammable materials.
▶ Do not lay the hot accessory tool down on highly inflammable materials.
WARNING
Risk of injury! Risk of burning injuries caused by hot surfaces.
▶ Avoid touching the guide tube as this part gets hot through use of the power tool.
1. Open the locking bar.
2. Pull the accessory tool out of the chuck.
5.2 Detachable supply cord
CAUTION
Risk of injury! Due to leakage current as a result of dirty contacts.
▶ Connect the detachable electric connector to the electric tool only when it is clean and dry and
when the supply cord is unplugged from the power outlet.
▶ Connect / disconnect the detachable supply cord.
Printed: 07.02.2017 | Doc-Nr: PUB / 5070871 / 000 / 03
3
4
English
15

Advertisement

loading