Water Temperature: Max 100° C; Log Check Sheet - Trane GVAF Series Installation Operation & Maintenance

R134a-r1234ze-r513a air cooled high speed centrifugal chiller
Table of Contents

Advertisement

Log Check Sheet

The operator log sheet are included for use as appropriate, for installation completion verification before
Trane Start-up is scheduled, and for reference during the Trane Start-up.
Operator Log
Sintesis GVAF chiller with UC800 Controller - Tracer AdaptiView Reports - Log Sheet
FWD
Power supply
Capacities
Cooling capacity on water (1)
Active Chilled Water Setpoint
Heating capacity on water (2)
Entering Water Temperature
Leaving Water Temperature
Fan motor
Ckt 1
Fan power input (3)
Saturated Refrigerant Temperature (°C)
Current amps (3)
Refrigerant Pressure (kPa)
Start-up amps
Approach Temperature (°C)
Water flow Status
Air flow
EXV % Open
minimum
Ckt 2
nominal
Saturated Refrigerant Temperature (°C)
maximum
Refrigerant Pressure (psia)
Main coil
Approach Temperature (°C)
Water flow Status
Water entering/leaving connections
EXV % Open
Electric heater (accessory for blower only)
Outdoor Temperature
Electric power supply
Ckt 1
Air flow (%)
Heating capacity
Saturated Refrigerant Temperature (°C)
Hot water coil (accessory for blower only)
Refrigerant Pressure (kPa)
Heating capacity (4)
Subcooling in °C
G2 filter (filter box accessory)
Ckt 2
Air flow (%)
Quantity
Saturated Refrigerant Temperature (°C)
Dimensions ( LxWxth)
Refrigerant Pressure (kPa)
G4 filter (filter box accessory)
Subcooling in °C
Quantity
Dimensions ( LxWxth)
Running Status
Starts
Condensate pump (accessory)
Running Time (Hr:min)
Water flow - lift height
Not available for FWD30 and FWD45
Running Status
Sound level (L/M/H speed)
Starts
Running Time (Hr:min)
Sound pressure level (5)
Sound power level (5)
Active Demand Limit Setpoint
Unit dimensions
Average Motor Current (%)
Width x Depth
Percent Speed
AFD Average Input Current (Amps)
Height
AFD Average Input Voltage (Volts)
Shipped unit dimensions
AFD Input Power (KW)
Width x Depth
AFD Output Power (KW)
Height
AFD Speed (rpm)
Weight
Active Demand Limit Setpoint
Colour
Average Motor Current (%)
Recommended fuse size
Percent Speed
Unit alone (aM/gI)
AFD Average Input Current (Amps)
AFD Average Input Voltage (Volts)
Unit with electric heater (gI)
AFD Input Power (KW)
AFD Output Power (KW)
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
AFD Speed (rpm)
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
Running Status
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
Starts
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
Running Time (Hr:min)
Oil Pressure (psia)
Heat exchanger operating limits:
FWD:
Running Status
*water temperature: max 100° C
Starts
*absolute service pressure: min 1 bar/max 11 bars
Running Time (Hr:min)
Accessories - Hot water coil:
Active Demand Limit Setpoint
*water temperature: min. +2° C/max. 100° C
Average Motor Current (%)
Percent Speed
*absolute service pressure: min 1 bar/max 11 bars
AFD Average Input Current (Amps)
AFD Average Input Voltage (Volts)
AFD Input Power (KW)
AFD Output Power (KW)
AFD Speed (rpm)
Active Demand Limit Setpoint
Average Motor Current (%)
Percent Speed
AFD Average Input Current (Amps)
AFD Average Input Voltage (Volts)
AFD Input Power (KW)
AFD Output Power (KW)
AFD Speed (rpm)
Date:
Technician:
Owner:
4
54
Technical Data
08
Start
(V/Ph/Hz)
Evaporator
(kW)
5,2
(kW)
6,3
(type)
(kW)
0,23
(A)
1,1
(A)
3,2
(m
/h)
490
3
(m
/h)
820
3
(m
/h)
980
3
(type)
(Dia)
3/4"
Condenser
(V/Ph/Hz)
230/1/50
(kW)
2/4
(kW)
6,3
2
(mm)
386x221x8
-
Compressor 1A
(mm)
-
(type)
(l/h - mm)
Compressor 1B
(dB(A))
36/40/43
Motor 1A
(dB(A))
46/50/53
(mm)
890 x 600
(mm)
250
(mm)
933 x 644
(mm)
260
Motor 1B
(kg)
32
(A)
8/16
(A)
16 (2kW),25 (4kW)
Compressor 2A
Compressor 2B
Motor 2A
Motor 2B
12
20
15 minutes
30 minutes
230/1/50
8,3
15
11,9
18,9
2 x direct drive centrifugal
0,46
0,65
2,2
3,1
5,5
9,3
980
1400
1650
2300
1970
2600
ISO R7 rotating female
3/4"
1 1/2"
230/1/50 or 400/3/50
400/3/50
8
10
12
17,4
2
2
486x271x8
586x321x8
2
2
486x264x48
586x314x48
Centrifugal
24 - 500
38/41/44
46/50/53
48/51/54
56/60/63
1090 x 710
1290 x 820
300
350
1133 x 754
1333 x 864
310
360
46
61
galvanised steel
8/16
8/16
40 (230V),3*16 (400V)
3*20
30
45
1 hour
18,8
30,1
20,9
38,2
1,04
1,51
4,7
5,5
14,1
16,5
1800
2700
3000
4500
3600
5400
1 1/2"
1 1/2"
400/3/50
400/3/50
12
12
22,4
34,5
2
2
586*421*8
586*621*8
2
2
586*414*48
586*614*48
47/52/57
47/52/58
57/62/67
57/62/68
1290 x 970
1290 x 1090
450
650
1333 x 1008
1333*1133
460
660
76
118
8/25
8/25
3*25
3*25
CTV-SVX009D-GB
UNT-PRC002-GB