ENDA EU SERIES PID UNIVERSAL CONTROLLER
ENDA EUP Series U
Thank you for choosing
Dual setpoint value can be selected.
PT100 ,J, K, L, T, S, R sensor (
0-20mA, 4-20mA, 0-10V, 2-10V, 0-25mV and 0-50mV input selections.
Auto calculation for PID parameters (SELF TUNE).
Self tune for automatic PID calculation or
manually enter PID parameters if known.
Three different feature can be assigned to digital input.
Three different feature can be assigned to F function key.
Soft-Start feature.
Analogue, SSR or Relay Output Control selection.
0-20mA and 4-20mA Analogue Output Control selection.
Up to 16 steps Profile Control.
A1 Relay output
programmable
C/A2 Relay output can be used as second Alarm or Temperature Control output.
Heating/Cooling control selection.
Zero point input shift
.
In case of sensor failure, periodically, auto-periodically running or relay state can be selected.
Rs485 Modbus RTU communication protocol feature (Specify at order).
Order Code : EUP
4
2 0
1
1 - Size
2 -
Supply Voltage
4420.....48x48x87mm
230VAC...90 - 250V AC
7420.....72x72x97mm
SM...........9-30V DC /
8420.....48x96x87mm
9420.....96x96x50mm
Input Type
PT100 Resistance Thermometer
PT100 Resistance Thermometer
J (Fe-CuNi)
Thermocouple
J (Fe-CuNi)
Thermocouple
K (NiCr-Ni)
Thermocouple
K (NiCr-Ni)
Thermocouple
L (Fe-CuNi)
Thermocouple
L (Fe-CuNi)
Thermocouple
T (Cu-CuNi)
Thermocouple
T (Cu-CuNi)
Thermocouple
S (Pt10Rh-Pt) Thermocouple
R (Pt13Rh-Pt) Thermocouple
0-20mA input
4-20mA input
0-10V input
2-10V input
0-25mV input
0-50mV input
ENVIRONMENTAL CONDITIONS
Ambient/storage temperature
0 ... +50°C/-25 ... +70°C
Max. Relative humidity
Relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.
Rated pollution degree
According to EN 60529;
Height
Max. 2000m
KEEP AWAY device from exposed to corrosive, volatile and flammable gases or liquids and DO NOT USE the device in similar hazardous locations.
ELECTRICAL CHARACTERISTICS
Supply
90-250V AC, 50/60Hz or 9-30VDC / 7-24VAC %10 SMPS
Power consumption
Max. 5VA
Wiring
Power screw-terminal connections: 2.5mm²', Signal screw-terminal connections: 1,5mm².
Line resistance
Max.
Data retention
EEPROM (minimum 10 years)
EMC
EN 61326-1: 2013 (Performance criterion B satisfied for EN 61000-4-3 standard).
Safety requirements
EN 61010-1: 2010 (Pollution degree 2, overvoltage category II)
OUTPUTS
C/A2 Output
Relay : 250V AC, 8A (for resistive load), NO+NC (Control or Alarm2 Output selection).
A1 Output
Relay : 250V AC, 8A (for resistive load), NO (Alarm1 and Cooling Control Output selection).
ANL/SSR Output
Max. SSR Output ; 0-20mA, 4-20mA, 24V 20mA. Max. load resistance ; 600 Ohm (12 bit 0.2% accuracy).
Life expectancy for relay
Without load 30.000.000 switching; 250V AC, A (resistive load) 300.000 switching.
CONTROL
C
ontrol
type
Single Setpoint and Alarm Control.
Control algorithm
On-Off / P, PI, PD, PID (selection).
A/D converter
14
Sampling time
Min. 1
Proportional band
Can be adjusted between
Control period
Can be adjusted between
Hysteresis
Can be adjusted between 1 and 50°C/F.
Output power
Setpoint value ratio can be adjusted between %0 and %100 .
HOUSING
Housing type
Suitable for flush-panel mounting according to DIN 43 700.
EUP4420 : W48xH48xD87mm, EUP7420 : W72xH72xD97mm,
Dimensions
EUP8420 : W48xH96xD87mm, EUP9420 : W96xH96xD50mm.
Weight
Approx. 400g (250g for EUP4400) After packing.
Enclosure material
Self extinguishing plastics
DO NOT clean the device with solvent (thinner, gasoline, acid etc.) and / or abrasive cleaning agents.
SURAN
Industrieelektronik
Dettinger Str. 9 / D-72160 Horb a.N
P
niversal ontroller
C
thermocouple
) types can be selected.
as first Alarm or Cooling control output.
2
3
3 -
Modbus (Optional)
RS.....
...
RS-485
Modbus Available
(Optional / Specify at order).
7-24V AC
Blank
....
N/A
Scale Range
°C
-199.9...600.0
EN 60751
-200...600
EN 60751
-30.0....600.0°C
EN 60584
-30....600°C
EN 60584
-30.0...999.9°C
EN 60584
-30...1300°C
EN 60584
-30.0....600.0°C
DIN 43710
DIN 43710
-30....600°C
EN 60584
-30.0...400.0°C
-30....400°C
EN 60584
EN 60584
-40...1700°C
-40...1700°C
EN 60584
-1999...+9999 (max. scale range 10000)
-1999...+9999 (max. scale range 10000)
-1999...+9999 (max. scale range 10000)
-1999...+9999 (max. scale range 10000)
-1999...+9999 (max. scale range 10000)
-1999...+9999 (max. scale range 10000)
Front panel
100
O
hm
bit
.
00ms
.
%0
.0 and
%100
1
and 125secs.
Tel.: +49 (0)7451 / 625 617
Fax: +49 (0)7451 / 625 0650
Devices
.
Please see EUPx420
Series Modbus Address
Map and Connection
Diagram Guide for
Modbus feature.
°F
°C
-199.9...999.9
°F
°C
-328....1112
°F
-22.0....999.9 °F
-22....1112 °F
-22.0....999.9 °F
-22....2372 °F
-22.0....999.9 °F
-22....1112 °F
-22.0....752.0 °F
-22......752
°F
-40....3092
°F
-40....3092
°F
:
IP6
5,
Rear panel :
IP20
±
8
.0 . If
Pb=%0
.0 , ON OFF c
-
ontrol
E-mail : info@suran-elektronik.de
Internet : www.suran-elektronik.de
EUP4420
C/A2
1200
SSR
PV
1200
A1
SV
SET
A1
DEL.
A2
INS.
C/A SET
F
START
STOP
ENDA
UNIVERSAL CONTROLLER
EUP8420
ENDA
PV
C/A2
SV
SSR
A1
SSR
C/A2
A1
SET
SET
A1
DEL. A2
INS.
C/A SET
C/A SET
F
START
STOP
ENDA
UNIVERSAL CONTROLLER
Accuracy
0,2% (
for full scale
)
0,2% (
for full scale
)
0,5% (for full scale)
0,5% (for full scale)
0,5% (for full scale)
0,5% (for full scale)
0,5% (for full scale)
0,5% (for full scale)
0,5% (for full scale)
0,5% (for full scale)
0,5% (for full scale)
0,5% (for full scale)
0,2% (
for full scale
)
0,2% (
for full scale
)
0,2% (
for full scale
)
0,2% (
for full scale
)
0,2% (
for full scale
)
0,2% (
for full scale
)
is selected.
english
EUP7420
PV
SV
C/A2
SSR
A1
A1
DEL. A2
INS.
SET
F
C/A SET
START
STOP
ENDA
UNIVERSAL CONTROLLER
EUP9420
PV
SV
UNIVERSAL CONTROLLER
A1
DEL.
A
2
INS.
F
START
STOP
1 digit
1 digit
1 digit
1 digit
1 digit
1 digit
1 digit
1 digit
1 digit
1 digit
1 digit
1 digit
1 digit
1 digit
1 digit
1 digit
1 digit
1 digit
1. / 7
EUPx420-E-03052019
Need help?
Do you have a question about the ENDA EUP Series and is the answer not in the manual?
Questions and answers