Wittenstein alpha Advanced SP+ ATEX MF Series Operating Manual page 53

Table of Contents

Advertisement

+
SP
ATEX MF
Operating noise L
(For n
= 3000 min
1
Max. permissible housing temperature
[°C]
Ambient temperature [°C]
Lubrication
Direction of rotation
Mass moment of inertia J
Refers to the drive
a
In the case of mounting position V1, reduce the average drive speed n
b
No-load running torques diminish during operation
c
Refers to the center of the output shaft or flange
Tbl-35: SP
Revision: 07
Technical data for SP
[dB(A)]
PA
-1
w/o load)
2
[kgcm
]
1
+
180, 2-stage, i = 40 – 100: Technical data for use in potentially explosive atmospheres
2022-D014984
+
180, 2-stage, i = 40 – 100
Clam-
ping
40
50
hub Ø
[mm]
see chapter 10.4 "Specifications for
startup and operation"
synthetic gear oil (see also Chapter 7.1
"Maintenance schedule")
In- and output same direction
24
5.5
5.5
32
8.7
9.7
38
9.7
9.7
Appendix
Ratio i
64
70
100
≤ 66
+80
5.5
5.4
5.4
8.6
8.6
8.5
9.7
9.6
9.6
by 20%.