Name Plate; Atex Marking For Use In Potentially Explosive Gas Atmospheres - Wittenstein alpha Advanced SP+ ATEX MF Series Operating Manual

Table of Contents

Advertisement

Description of the gearbox
3.2

Name plate

The identification plate is attached to the gear housing or the input flange.
A
C
F
A
Ordering code (see Chapter 3.3
B
C
D
E
F

3.2.1 ATEX marking for use in potentially explosive gas atmospheres

II 2G Ex h IIC T3 Gb X
en-10
SP 100E-MF1-4
-0G1-2S
Lubrication: Oil Castrol Optigear Synthetic 800/220
SN: 1234567
DMF: 04/19
WITTENSTEIN alpha GmbH - Walter-Wittenstein-Str.1 - 97999 Igersheim
G
K
"Ordering code")
Ratio i
Lubricant
Amount of lubricant
ATEX marking
Serial number
Tbl-4: Name plate (sample values)
L
M
N
O
Tbl-5: Name plate (sample values)
2022-D014984
B
D
i = 4
95 ccm
Made in Germany
T : 252 Nm / n
G
Production date KW/JJ
Maximum permitted gear output
H
torque T
Maximum permitted drive speed
I
n
1Max
J
K
L
Equipment category
"Ex h: non-electrical"
M
"II: Flammable materials: gases /
P
"C: a typical gas is hydrogen"
N
Temperature class
"T3: Max. surface temperature
O
Equipment protection level (EPL)
Use in zone 1: "listed ignition sources
under normal operation and in the event
of expected malfunctions"
P
Restrictions regarding ambient
temperature and mounting position
(see Chapter 10.4 "Specifications for
startup and operation" )
+
SP
ATEX MF
E
II 2G Ex h IIC T3 Gb X
II 2D Ex h IIIC T150 °C Db X
: 2900rpm
1max
2B
I
H
J
2B
CE identification
Manufacturer
Designation
Equipment group
vapors"
Subgroup
≤?200?°C"
Revision: 07