Chapter 6 Usage; Before Use The Device - OSEE IRS Series User Manual

Intelligent matrix switcher
Table of Contents

Advertisement

Chapter 6 Usage

6.1 Before Use the Device

1.
There are two ways for connecting between the host and the swithers.
1) Connect by RS485 interface. The devices connected via BNC interface. And in this way, the
remote control panel should use an external power adapter.
2) Connect by RJ45 interface.In this way, the remote control panel does not require an external
power supply.
2.
If the matrix switcher would be used as the host, the ID of it must be set to 0, and there is only one
host device in a system.
3.
When the matrix switcher and the remote control panel are used in a group, each device has one
ID, and the DIP switch range is 0 to 15.
4.
A crossover cable should be used between the host matrix switcher and the matrix switcher of the
first-level cascade, while the connection between the matrix switchers in the next cascade level
would use a straight-through cable. The Line orders of the crossover cable are 3 to 5, and 4 to 6.
5.
The matrix switchers and the remote control panels are required cascading by the RS485 interface
and the cascaded remote control panels use the straight-through cable.
6.
Only through the IP of the host, the entire system network page could be viewed. Viewing the IP of
the slave device, only the information of the slave device could be seen.
7.
The matrix switchers with control panel are X/Y panel type. And the remote control panels contain
X/Y panel and PGM/PST panel two types. The two types of remote control panel can be set in the
WEB. The functions of the keys on the panel can also be defined through the WEB.
8.
The produces support up to 16-channel HD/SD/3G input signals. If the synchronize switch is
required, the synchronization reference signal should be inputed.
9.
The produces support up to 16-channel HD/SD/3G input signals. If the synchronize switch is
required, the synchronization reference signal should be inputed.
10. The matrix switchers with control panel are X/Y type panel. The keys contents SRC key, DST key,
target protective key, targeting key, and panel lock key.
11. Device Address: matrix switchers or remote control panels have an eight-digit DIP switch. The last
four digits used to set the device address. And thr range is 0 to 15. 0 indicates the host matrix
switcher; the other address indicates the other matrix switchers or the remote control panel. If the
first four positions are set on 1 at the same time, the matrix switcher would restore to the default
value and default IP: 192.168.1.86.
12. The two RS485 interface are used to install the Network connection between the matrix switchers
and the remote panels and the baud rate is 115200 bps. The RS422 interface is used to receive
serial network control data and the baud rate is 19200 bps.
13. When a matrix switcher and a remote control panel are used, the address of the matrix switcher
must be appropriated on to 0, and the remote control panel would be 1 to 15. For one-to-one
11