Energizer EDC12035 Instruction Manual

Energizer EDC12035 Instruction Manual

Programmable direct drive air compressor

Advertisement

Quick Links

IMPORTANT:
Questions, problems, missing parts or want technical service?
Before returning to your retailer, call our customer service
department at 1-866-295-6775.
Programmable Direct Drive
Air Compressor
EDC12035
INSTRUCTION
MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Energizer EDC12035

  • Page 1 EDC12035 Programmable Direct Drive Air Compressor IMPORTANT: INSTRUCTION Questions, problems, missing parts or want technical service? MANUAL Before returning to your retailer, call our customer service department at 1-866-295-6775.
  • Page 2: High-Pressure Applications

    HIGH-PRESSURE APPLICATIONS Car tires Bicycle tires Basketballs Sporting equipment Party balloons FEATURES...
  • Page 3: Operation

    Model no. EDC12035 / Contact us 1 866 295-6775 Hose Holder Carry Handle Pre-set Button (for Auto Pressure Setting Buttons Shut-off) Air Hose ▲/ ▼ Thread Connection 12 Volt Plug LED Button WARNING Never expose the air compressor to rain, frost or temperatures above 30 C (86 °F)
  • Page 4: Pressure Pre-Set

    Pressure Pre-Set and the Compressor will begin to operate. The Compressor will automatically shut The pre-set pressure is factory set at 45 off once the pre-set pressure is reached. PSI when manufactured. Press LED button for visibility in the Press button ‘set’ for 3 seconds to dark.
  • Page 5: Fuse Replacement

    Model no. EDC12035 / Contact us 1 866 295-6775 Adjust to your desired pressure. (Refer to Cylinder diameter: 30 mm Pressure Pre-Set) Fuse: 15 A Move the On/Off switch to ‘I’ position Performance: 0 to 30 PSI in approximate and the compressor will begin to operate.
  • Page 6 EDC12035 Compresseur d’air à entraînement direct programmable IMPORTANT : Vous avez des questions ou des problèmes? Il vous manque des pièces? Vous souhaitez un service technique? Avant de rendre cet article à votre détaillant, appelez notre service à la clientèle au...
  • Page 8 EDC12035 1 866 295-6775 Support de tuyau réparer ou remplacer par un technicien qualifié. N’exposez jamais le compresseur d’air à la pluie, au gel ou à une température supérieure à 30 °C (86 °F) ou inférieure à -30 °C (-22 °F).
  • Page 9 Préréglage de pression). Vissez le raccord fileté au corps de la valve du pneu. La pression est préréglée en usine à 45 lb/po². Appuyez sur le bouton de réglage pendant trois secondes pour vérifier la pression préréglée, qui est placée à...
  • Page 10 EDC12035 1 866 295-6775 par Bright Manufacturing, Fort Lauderdale, FL 33309 Energizer EDC12035...