ZyAura ZGm27 Operating Instructions

Mini 3 in 1 co2 monitor co2+temp.+rh

Advertisement

Quick Links

Mini 3 IN 1 CO

Device Overview

Thank you for selecting ZGm27 desktop CO
CO
concentration, ZGm27 can also measure the ambient temperature and the relative humidity (CO
2
detect the presence of CO
in ambient air and helps people to take care of Indoor Air Quality. ZGm27 can be widely used in the office building,
2
school, exhibition hall, shopping mall, meeting room, fitness center, restaurant and other public places where personal comfort and healthy are
important.

Features:

□ V Dual Beam NDIR (Non-Dispersive-Infrared) technology is being used to measure CO
□ V The Large LCD clearly displays the CO
□ V 3-color backlight (green / yellow / red) gradually changes color with CO
□ V "HISTORY" with 3 emotions indicates the status of CO
□ V "ECO" saving power function darken the LCD backlight during the period from 22:00 pm to 6:00am.
□ V 7-color backlight for options : white

Warnings:

□ V Please take off the AC power adapter and store it well when this CO
□ V This CO
monitor is for home use, not suitable for certifying the test results.
2
□ V If use this CO
monitor for testing, ZGm27 does not guarantee the test results.
2
1. LCD Display
4. Power Inlet (Micro USB Socket)
7. Humidity Sensor
Key description:
Select backlight display mode or setting modes.
(○
)
2
Adjust the parameters.
(○
)
3
LCD Display Symbol Description
Symbol
Monitor (CO
2
monitor. ZGm27 CO
2
concentration, temperature, relative humidity and real-time clock.
2
2
turquoise
blue
à
à
2. Mode Key
5. Screw Position
8. Ventilation Slots
Meaning
CO
concentration, parts per million (ppm)
2
Ambient temperature
Relative humidity
Real-time setting display
Three emoticons
History: 24-hour Historical Chart
LCD backlight color
CO
concentration alarm
2
+Temp.+RH) Operating Instructions
2
monitor is smart, compact and easy-to-use. In addition to measuring the
2
concentration.
2
records up to 24 hours.
purple
red
yellow
à
à
à
à
monitor left idle for long.
2
ambient CO
2
Ambient temperature
Relative humidity
Real-time 24-hour clock (hour/minute)
The status of recorded CO
<800ppm
Bar graph displays indicate the status of CO
A total of 7 colors are optional.
CO
concentration alarm settings
2
+Temp.+RH). This device is developed to
2
concentration and improve the long term stability.
2
green.
3. Select Key
6. Calibration Gas Entry
Description
concentration
concentration
2
800ppm~1,400ppm
>1400ppm
records up to 24 hours
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZGm27 and is the answer not in the manual?

Questions and answers

Summary of Contents for ZyAura ZGm27

  • Page 1 CO in ambient air and helps people to take care of Indoor Air Quality. ZGm27 can be widely used in the office building, school, exhibition hall, shopping mall, meeting room, fitness center, restaurant and other public places where personal comfort and healthy are important.
  • Page 2 Energy-saving The LCD backlight will be dark during the specific period. Background calibration Change calibration and ABC setting Calibrate the sensor while the reading deviates from the actual gas parameter. concentration. Automatic background calibration Operation Instructions 1. Power on and Measure: Connect the USB cable to a PC or a USB to wall adapter to power on the device.
  • Page 3 (Figure 5) (Figure 6) (Figure 7) (Figure 8) 6.2 CLr: When "CAL" icon flashes on the LCD, press Select key (○ ) 1 time to select "CLr" (Figure 9), and then press Mode key to confirm it. The “dn” icon is displayed on the LCD, indicating that the background calibration value has been cleared. (Figure 10) (Figure 9) (Figure 10) 6.3 AbC: When "CAL"...
  • Page 4 Please see「Dimension」section to check the distance between the screws. Weight & Dimension Weight: 86g Dimensions: Fault Codes & Troubleshooting Guide This section includes a list of Frequently Asked Questions for problems you may encounter with the ZGm27 CO monitor. Fault Icon Description of The Fault Suggested Actions This device of CO measurement abnormality.

Table of Contents