ZyAura ZG106 Operating Instructions

Co2 and temperature monitor

Advertisement

Quick Links

ZG106 CO
ZG106 is a portable, accurate handheld CO
ambient temperature. It uses Dual Beam NDIR technology to improve the long term stability.

Features:

The built-in Data logger can store 48 sets of CO
V
□ V Max/Min mode can record the maximum and minimum concentration of CO
□ V The Alarm mode will sound at 1000 PPM, the ASHRAE limit. The Alarm Level can be modified, and the Alarm sound can be turned off.
□ V The RCFS Mode can recover the original factory settings after the CO
(Display Features and Modes)

MODE FUNCTIONS

There are several Modes which we can adjust the setting parameters. These modes are Alti Mode, Alarm Mode, Outside Mode, Ucal Mode,
Datalogger Mode, MaxMin Mode and rcFS Mode in sequence.
ALTI
Compensate the pressure changes with appropriate altitude of location when measure.
Alarm while CO
ALARM
The Alarm sound can be turn on/off while the "speaker Icon" flashes.
OUTSIDE
Modify the outside CO
CALI
Calibrate the sensor while the reading deviates from the actual CO
DATALOGGER
Show the past CO
MaxMin
Show the Max and Min CO
rcFS
Recover the factory setting, if the device cannot show accurate reading.

OPERATION INSTRUCTIONS

PowerOn
Press Power button (○
) to turn on the device after placing 4 AA batteries into the battery holder or AC adapter plug into the DC socket.
1
Once power on, CO
reading will show after 15 seconds of warm up.
2
WarmUp
It lasts approximately 1min before WARMUP disappears; all the functions will not response during warm up.
UserMode
After warm up, the device will stabilize and display the normal CO
and Temperature Monitor Operating Instructions
2
monitor. In addition to measuring the CO
2
and temperature in the past 24 hours; one log per 30 minutes.
2
1. Power Button
6. LCD Display
2. Enter Button
7. LED Light
3. Down Button
8. Function Label
4. Up Button
9. Gas Entry Hole
5. Mode Button
10. Power inlet
concentration exceed one threshold, which can be modified.
2
concentration, for defining the ventilation rate.
2
and Temperature records in the past 24 hours.
2
reading before being cleared or powered off after PowerOn.
2
concentration, this device can also measure the
2
since the device has been last turned on.
2
device has been recalibrated, altered, or damaged.
2
11. RJ45 socket
12. Housing Stand
13. Battery Cover
14. AA Batteries*4
concentration.
2
Reading (Upper Display) - remain visible at all times.
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZG106 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ZyAura ZG106

  • Page 1 ZG106 CO and Temperature Monitor Operating Instructions ZG106 is a portable, accurate handheld CO monitor. In addition to measuring the CO concentration, this device can also measure the ambient temperature. It uses Dual Beam NDIR technology to improve the long term stability.
  • Page 2 Temp and Ventilation Rates (Lower Display) ■ The Up/Down button (○ /○ ) allows you to scroll through the Temperature and Ventilation Modes. When pressing the Up button, the lower display will go through the following sequence: Temp°C -> Temp°F -> Vent Rate lps -> Vent Rate cfm/p *Note: lps refers to Liter Per Second Per Person;...
  • Page 3: Power Supply

    If the error message remains please contact the Service Department for further assistance. 「 」 Radiant Innovation Inc. Http://www.ZyAura.com 1F, No.3, Industrial East 9 Road, Science-Based Industrial Park, HsinChu, Taiwan 300. Ref.No.:082019...

Table of Contents