Towable-OEM-40-60-80A.book Page 7 Monday, March 5, 2007 12:15 PM
A
Specifications
Specifications are subject to change without notice.

Mechanical Specifications

Physical Specifications
Weight
Operating temperature range
Length
Width
Height

Electrical Performance

AC Input
Input current (at rated output)
Nominal input voltage
Normal operating input voltage
Min. operating input voltage
Max. operating input voltage
Power factor (rated output, nominal input)
Safe (non-operating) input voltage range
Frequency
XADC-40
XADC-60
7.9 lb
8.2 lb
(3.6 kg)
(3.7 kg)
14 ºF – 86 ºF (-10 ºC – 30 ºC)
de-rated 86 ºF – 140ºF (30 ºC – 60 ºC)
> 140ºF (60 ºC) unit may shut down
11 13/16 in. (300.0 mm)
7 1/8 in. (180.0 mm)
4 3/4 in. (120.0 mm)
XADC-40
XADC-60
6 Aac
9 Aac
120 Vac, 60 Hz
108 Vac – 130 Vac
90 Vac
140 Vac
≥ 0.95
0 – 150 Vrms
50 – 70 Hz
XADC-80
8.3 lb
(3.8 kg)
XADC-80
12 Aac
7