WARNING: CAUTION: THE PUMP SHOULD BE INSTALLED ACCORDING TO YOUR LOCAL ELECTRICAL INSTALLATION ORDINANCES AND REGULATIONS. ONLY QUALIFIED, LICENSED PERSONNEL SHOULD INSTALL PUMP AND WIRING. 1) Locate pump as close to pool as possible, preferably in a dry, well ventilated area away from direct sunlight.
1 Pump Installation - Please install on a level vibration free surface. - Allow use of short, direct suction pipe. (To reduce friction losses & don't install the pump at more than 3m geometrical height from water level) - Allow for gate valves in suction and discharge piping if required. - Have adequate floor drainage to prevent flooding.
3. Menu structure 3.1 Program Flow Chart Self Checking Interface (~3 seconds) Short press MODE to change page " " E.g. "SP:1000" Monitoring Interface Speed Display Unit: RPM E.g. "P: 0" Power Consumption Display Unit: Watt (W) (Long press "MODE" for 2 seconds) Time Display E.g.
Page 7
3.2 Buttons Control Setting Error/Auto Action Monitoring Interface Edit Interface Interface Recovery Add current Short press “UP” Current speed +10rpm Page Up value Current speed increase Add current Long press “UP” Page Up rapidly rapidly value rapidly Reduce current Short press “DOWN” Current speed -10rpm Page Down value...
4 Programming 4.1 Programmed Schedule 2 schedule settings available, preset speed at 1500RPM, 2400RPM. 2) Each schedule setting has 4 parameters “Running Speed”, “Time On”, “Time Off”, Enable / Disable. 3) Programmed Schedule Priority: Schedule 1 > Schedule 2 . 4) Programmed Schedule Logic: If more than 1 schedule is enabled within the same time period, the controller will operate only with the highest priority schedule and speed, the corresponding indication light will on.
content flash, short press “Mode” again, reset complete. Short press “Speed 3” while the content is flashing to stop the reset. 5 Fault treatment 5.1 Communication error When there is communication error between the controller and the variable speed driver, an error code “ER….”...
Page 10
(Diagram 6.2, Communication Error) 6.2 Monitoring Interface After starting, enter “Monitoring Interface”. As diagram 6.3. Short press “Mode” to interchange between speed or time display page.As diagram 6.3-6.5. (Diagram 6.3, Speed display page) (Diagram 6.4, Power consumption display page) (Diagram 6.5, Time display page) Short press “Speed1”...
Page 11
At any time press “Up” or “Down”, to add or reduce the rpm by 10, as diagram 6.10-6.11. (Diagram 6.10, 1000rpm press “Up” once) (Diagram 6.11, 1000rpm press “Down” once) Long press “Mode”, to enter the setting interface, as diagram 6.12. 6.3 Setting Interface Short press “Mode”...
(Diagram 6.25, Auto Recovery, error details OC1, (Diagram 6.26, Auto Recovery count down, error time 1) 5 seconds remaining) (Diagram 6.27, Auto Start count down, 5 seconds remaining) Error Menu Error Menu display as diagram 6.28, error details will be displayed and all lights will be flashing. Short press “Run”...
9 Trouble Shooting MOTOR DOES NOT START LOW PUMP CAPACITY 1) Disconnect switch or circuit breaker in off 1) Valve in suction or discharge line partly position closed 2) Fuses blown or thermal overload open 2) Suction or discharge line partly plugged 3) Locked motor shaft 3) Suction or discharge line too small 4) Motor windings burned out...
10 Replacement Parts 10.1 Parts Diagram 9 10 11 12 13 14 10.2 Parts Listing Product Description Item NO. Part NO. Nut for Lid 01021143 Transparent Lid 01041057 02010253 O-Ring for Lid 01112080 Basket 89023801 1.5" Union Pump body 01021144 89021307 Drain Plug with O-ring 02010245...