Connecting Switch
1. Deactivate power to heat pump.
2. Plumb the switch as indicated in accessories installation
instructions.
3. Remove heat pump electrical access panel.
4. Using two of the three wires from the installed switch, route
wires to the low voltage side of the electrical enclosure. The
third wire is not used. Follow all National Electric Codes
(NEC) unless State or Local guidelines supersede.
5. Connect the wires to the jumper provided. Polarity is not
important.
6. Reattach heat pump access panel.
7. Apply power to heat pump.
8. Configure the heat pump to accept the pool/spa relay switch.
See "Configuring Switch" below.
Configuring Switch
Enter "Installer Menus", then proceed
Dry Contact Connection Points to the
Microprocessor
Page - 42