Pump Neutral Adjustment - Danfoss MCV111B Series Manual

Electrical displacement control-pv for 90 series
Table of Contents

Advertisement

MOUNTING (continued)
TO INSTALL THE NEW CONTROL
1.
Place a new gasket on the pump housing. Ensure that
the control orifice and spring are in the proper position in
the control.
2.
Engage the pin on the control linkage in the mating hole
in the link attached to the swashplate. To ensure that
linkage is engaged before adding mounting bolts simply
place a finger under the electrical input connection and
lightly lift. If the control moves more than 3/8-inch the pin
is not engaged. Try again. See the Control Linkage
Assembly photograph.
3.
Ensure that the pin is engaged in the link by tilting the
control upwards from the pilot valve end. If the pin
CONTROL LINKAGE ASSEMBLY
Assembly of Control Linkage.

PUMP NEUTRAL ADJUSTMENT

Use the following procedure to bring the pump to neutral
once the electrical displacement control has been mounted.
1.
Install a 600 psi gauge into the charge pressure gauge
port on the pump.
photograph.
2.
Using a 10 mm wrench, loosen the hex lock nut on the
null adjustment screw. See the Dimension drawings.
3.
Disconnect the electrical source at the connector.
4.
Start the prime mover and run at low idle.
BLN-95-8995-4
See the Pump Port Location
catches in the link and allows only a slight upward tilt,
there is positive engagement. If the control swings up
freely, the pin is not properly aligned.
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4
Ensure positive pin engagement. Failure to do so may
result in pump output, and the vehicle may move.
4.
Position the control into place against the pump housing.
Align the gasket. Install the cap screws (On 42 cc and
180/250 cc pumps use the included seal washer per
the Seal Washer Location drawing) and torque to 10-12
ft-lbs.
SEAL WASHER LOCATION
SEAL WASHER
(USED ON 42, 180, AND
250 cc MODELS ONLY)
1394
Location of Seal Washer on 42, 180, and 250 cc
Pump EDCs.
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4
To adjust neutral requires operating the pump. Take the
necessary safety precautions, such as having
unnecessary personnel stand away from the machine.
Maximum system pressure may occur upon start-up,
and the machine may move. Ensure that the operator is
not in a position to be injured should the machine move.
5.
Warm the system up for several minutes to bleed air.
6.
Slowly increase the prime mover speed to rated rpm.
8
WARNING
WARNING
1396