5.2.2. Configuration of the I/O Contacts tab

(1)
Standby Status for Internal
Load Impedance (Backup 1)
This
connects
or
impedance load to the line out of the
backup
amplifier.
whenever surveillance of the internal
status
of
backup
required. In this case, once the COU-
02/0ETH has been configured, it will
be necessary to set the surveillance
of backup amplifier 1.
(2)
Standby Status for Internal
Load Impedance (Backup 2)
This
connects
or
impedance load to the line out of the
backup
amplifier.
whenever surveillance of the internal
status
of
backup
required. In this case, once the COU-
02/0ETH has been configured, it will be necessary to set the surveillance of backup amplifier 2.
Configuration of a contact
1. Configure the functionality of the contact as an input or output
contact (3).
2. Open the drop-down menu (4) and select the functionality
required.
Backup Amplifier Fail.
The FAIL contact of the backup amplifier must be connected to
this contact. In this way, when the backup amplifier has a fault,
the front FAIL LED corresponding to the backup amplifier lights,
and if this backup amplifier were to be in use, the loudspeaker
line of the switched zone would be disconnected from the backup
amplifier.
Internal Load Impedance Disconnection.
Activation of the contact disconnects the load impedance of the
backup amplifier.
3. Click on the button Config. (5) and proceed to configure the contact:
1. Enter a name to identify the contact (6).
2. Select a default status for the contact (7)
(NO: Normally open, NC: Normally closed).
3. Open the drop-down menu (8) and select the associated amplifier:
If the functionality selected is Backup Amplifier Fail, select the backup amplifier whose FAIL contact is
connected to this contact.
If the functionality selected is Internal Load Impedance Disconnection, select the backup amplifier on
which you wish to disconnect the impedance load.
4. Click on OK.
COU-02/0ETH version 1.1
COU-02ETH
disconnects
an
Select
Connected
amplifier
1
is
disconnects
an
Select
Connected
amplifier
2
is
(1)
(4)
(3)
Ethernet controlled
(5)
(6)
R&D Department
change over unit
(2)
(7)
(8)
20