CHAPTER 2 TECHNICAL SPECIFICATIONS AND DIMENSIONS

General
Description
Application
Intended Use
Legal Metrology and Custody
Transfer
Functional Specification
Tank Database
Redundancy
Supported Gauge Models
Modbus Gauges
TRL/2 Gauges
Gauge Commands
Tank Scanning
Inventory Calculations
Tank Capacity Tables
(Strapping Tables)
Support API/ASTM Product
Calculations
Product Group E
Available Gauge Data
Part No.: 4417591_Rev10
Technical Specifications and Dimensions
2.1 Technical Specifications - Functional (Software version R140)
Field scanning and communication interface for tank Inventory applications with
optional embedded tank inventory calculation functionality.
For all applications requiring accurate and reliable process and inventory data, such as
refineries, tank farms and terminals. Data is suitable for custody transfer, safe product
transfer and tank farm operation.
Control room equipment.
Compliant to API standards as stated by approval and certification by notified bodies as
NMi.
80 tanks
Hot standby and real-time synchronization.
Switchover within 10 seconds.
All GPU enabled tank gauges (such as 811, 813, 865, 866, 854, 872, 873, 877, 894,
and 990)
Smartline level transmitter (SLG 700) via Moore HCS Modbus HART converter
Honeywell TRL/2 Radar gauge (990) and Rex gauge (Rex RTG)
-
Lock Test
-
Freeze
-
Alarm Test (SmartRadar)
-
Unlock
Max. 6 field ports sequential and/or parallel.
Conform API MPMS Ch. 12.1.
Up to 5,000 straps per tank. 400,000 straps total.
-
ASTM D1250-52 Table 23, 24, 53 and 54
-
ASTM D1250-1980; conform Vol. X - Tables, 5, 6, 23, 24, 53, 54, 59 and 60 and 59,
60 Alternative Temperature, product groups A, B, C, D
-
API MPMS Ch. 11.1 (2007; adj. to ASTM D1250-04 and IP-200) - Tables 5, 6, 23,
24, 53, 54, 59, 60 and 59, 60 Alternative Temperature, product groups A, B, C, D
-
API MPMS Ch. 11.2.4 (GPA TP-27) - Tables 5, 6, 23, 24, 53, 54, 59, 60 and 59, 60
Alternative Temperature
-
ASTM D4311-83 Table 1 and 2
-
ASTM D4311-96 Table 1
-
ASTM D4311-04 Table 1 and 2
-
Product Level
-
Product Temperature
-
Vapor Pressure
-
Water Level
-
Spot Temperatures
Introduction Manual
CIU 888
-
Calibrate (854, 894, 990)
-
Water Dip
-
Block
-
Density Dip
-
Gauge Status and Alarms
-
Vapor Temperature
-
Ambient Temperature
-
Observed Density (Servo, HTG, HIMS)