  • Page 1 Low Cost HOBBYIST Digital Multimeter QM1500...
  • Page 2 Low Cost Digital Multimeter User Manual Thank you for purchasing this Low Cost Digital Multimeter. This multimeter is the perfect introduction to meters, and data capture of standard measurements including DC and AC voltage, DC current, resistance, transistor, and diode testing. Just move the rotary switch to the correct position, plug in your leads and you’re good to go! Please familiarise yourself with the functions of the multimeter before use.
  • Page 3 FUNCTIONS Max. Display 2000 counts Basic Accuracy 0.500% DC Voltage Range 400mV - 1000V AC Voltage Range 4V - 1000V DC Current Range 4mA -10A AC Current Range 4mA - 10A Resistance 400Ω - 40MΩ Capacitance (CAP) 4nF - 100µF Frequency (Hz) Up to 10MHz...
  • Page 4 LCD Screen Function Switch COM Input Jack The tilt stand & battery compartment are at the rear of the multimeter.
  • Page 5 FUNCTIONS Autoranging/ • The meter’s default setting is autoranging. This Manual automatically selects the best range for the selected test/measurement. • To set the meter to manual, press the RANGE button. The ‘ A UTO’ icon on the screen will turn off. •...
  • Page 6 SYMBOL DESCRIPTION Continuity Diode Test Low Battery Farads (Capacitance) Ω Ohms Hertz (Frequency) Volts A, mA, µA Current Range Alternating Current/Voltage AUTO Autoranging Direct Current/Voltage HOLD Display Hold...
  • Page 7: Ac/Dc Voltage Measurement

    AC/DC VOLTAGE MEASUREMENT On some low AC and DC voltage ranges - when test leads are not connected to a device - the display on the screen may show a random, changing reading. This is normal and caused by high-input sensitivity of the multimeter. When connected to a circuit, the multimeter will display a stabilised, accurate measurement.
  • Page 8: Resistance Measurement

    • For current measurements up to 400mA, set the function switch to the mA position and insert the red test lead banana plug into the mA jack. • For current measurements up to 4000µA, set the function switch to the µA position and insert the red test lead banana plug into the µA jack.
  • Page 9: Diode Test

    DIODE TEST The value that displays on screen during the diode check is the forward voltage. 1) Set the function switch to the Ω CAP position. 2) Insert the black test lead banana plug into the negative COM jack. 3) Insert the red test lead banana plug into the positive VΩCAP jack. 4) Press the MODE button until display on the screen.
  • Page 10: Frequency Measurement

    FREQUENCY MEASUREMENT 1) Set the function switch to the HZ% position. 2) Insert the black test lead banana plug into the negative COM jack. 3) Insert the red test lead banana plug into the negative VΩCAP jack. 4) Touch the test probes to the circuit being tested. 5) Read the frequency displayed on the screen.
  • Page 11 AC VOLTAGE RANGE RESOLUTION ACCURACY 400mV/60mV 0.1mV 4V/600mV ±(1.0% reading + 3 digits) 40V/6V 10mV 400V/60V 100mV 1000V ±(1.2% reading + 5 digits) Input impedance: 10MΩ; Max. input voltage: 1000VAC RMS; Frequency range: 50~400Hz; all AC voltage ranges are specified from 5% of range to 100% of range.
  • Page 12 AC CURRENT RANGE RESOLUTION ACCURACY 400µA 0.1µA 4000µA 0.001mA ±(1.5% reading + 5 digits) 40mA 0.01mA 400mA 0.1mA 10mA ±(3.0% reading + 5 digits) Overload protection: fuse FF500mA/1000V fuse FF10A/500V. Frequency range: 50~400Hz RESISTANCE RANGE RESOLUTION ACCURACY 400Ω 0.1Ω ±(0.8% reading + 5 digits) 4kΩ...
  • Page 13 CAPACITANCE RANGE RESOLUTION ACCURACY 40nF 10pF ±(5.0% reading + 7 digits) 400nF 0.1nF 4µF ±(3.0% reading + 5 digits) 40µF 10nF 100µF 0.1µF ±(5.0% reading + 7 digits) Overload protection: 1000VDC or 1000VAC RMS FREQUENCY RANGE RESOLUTION ACCURACY 0.001Hz 40Hz 0.01Hz 400Hz 0.1Hz...
  • Page 14: Maintenance

    DIODE & CONTINUITY RANGE FUNCTION Display approximate forward voltage of diode Built-in buzzer will sound if resistance is less than 30Ω MAINTENANCE BATTERY INSTALLATION To avoid the false readings, replace the battery as soon as the low battery power indicator appears. 1) Turn the power off and disconnect the test leads from the meter.
  • Page 15: Specifications

    SPECIFICATIONS Display: 2000 Count Security Class: CatII 500V Basic DCV Accuracy: 0.500% DC Voltage: 200mV, 1000V (± 0.5%) AC Voltage: 200V, 750V (max input 750V RMS) (± 1.2%) DC Current: 200µA, 2mA, 20mA, 200mA, 10A (± 1.2%) Resistance: 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ (± 1.2%) Measurement Type: Average Input Impedence:...